Depth profile CF LIBS analysis of the wall deposited layer in the COMPASS tokamak after LiSn testing campaign

  1. 1.
    0581954 - ÚFP 2024 RIV NL eng J - Článek v odborném periodiku
    Shetty, N. - Veis, M. - Atikukke, S. - Bartoň, Petr - Jeřáb, Martin - Dejarnac, Renaud - Veis, P.
    Depth profile CF LIBS analysis of the wall deposited layer in the COMPASS tokamak after LiSn testing campaign.
    Nuclear Materials and Energy. Roč. 37, December (2023), č. článku 101547. E-ISSN 2352-1791
    Institucionální podpora: RVO:61389021
    Klíčová slova: Calibration free (CF) approach * Deposited layer analysis * Depth profile * Fusion plasma wall interaction * Laser-induced breakdown spectroscopy (LIBS) * Li and Sn migration * Liquid metal divertor (LMD)
    Obor OECD: Fluids and plasma physics (including surface physics)
    Impakt faktor: 2.6, rok: 2022
    Způsob publikování: Open access
    https://www.sciencedirect.com/science/article/pii/S2352179123001862?via%3Dihub

    Plasma-facing materials in tokamak nuclear reactors are subject to intense heat and radiation. The design of liquid metal (LM) divertor walls has several advantages over the solid counterparts. It is important to understand the migration and re-deposition of LMs such as lithium (Li), lead (Pb) or even tin (Sn). This work presents CF LIBS depth profile analysis of the deposited layer on Ni–Cr based screws situated at different places in the COMPASS tokamak vessel during the Capillary Porous System (CPS) LM (LiSn) divertor testing campaign. The experiment was carried out at low Ar pressure (100 mbar) using ns Nd:YAG laser operating at 532 nm. The spectra were recorded using echelle spectrometer (M5000, Andor Tech.) equipped with an iCCD camera (iStar DH743, Andor Tech.). The quantification was based on observed C I, B I, Li I and (weak) Sn I lines, in addition to trace elements (Ca, Na, K) and main matrix elements (Cr, Ni, Fe). The evaluation of electron temperature and density was based on Cr I-II, Ni-II and Fe I-II lines. The LM based content is estimated to be Li (0.3-0.81 at.%) and Sn (0.1-0.23 at.%) with Li/Sn at.% ratio ranging from 3 to 3.5 (wt.% ratio of 0.17-0.20). In practise, the limit of detection of Sn by CF LIBS for this type of Cr-Ni-Fe based matrix is observed to be ∼0.1 at.%.