Poly(3-hydroxybutyrate) (PHB) and Polycaprolactone (PCL) Based Blends for Tissue Engineering and Bone Medical Applications Processed by FDM 3D Printing

  1. 1.
    0581654 - ÚEM 2024 RIV CH eng J - Článek v odborném periodiku
    Krobot, Š. - Melcová, V. - Menčík, P. - Kontárová, S. - Rampichová, Michala - Hedvičáková, Věra - Mojžišová, M. - Baco, A. - Přikryl, P.
    Poly(3-hydroxybutyrate) (PHB) and Polycaprolactone (PCL) Based Blends for Tissue Engineering and Bone Medical Applications Processed by FDM 3D Printing.
    Polymers. Roč. 15, č. 10 (2023), č. článku 2404. E-ISSN 2073-4360
    Institucionální podpora: RVO:68378041
    Klíčová slova: 3D printing * FDM * poly(3-hydroxybutyrate) * bone tissue engineering * scaffold * biocompatibility * polycaprolactone * polylactic acid
    Obor OECD: Biomaterials (as related to medical implants, devices, sensors)
    Impakt faktor: 5, rok: 2022
    Způsob publikování: Open access
    https://www.mdpi.com/2073-4360/15/10/2404

    In the presented work, poly(3-hydroxybutyrate)-PHB-based composite blends for bone medical applications and tissue engineering are prepared and characterized. PHB used for the work was in two cases commercial and, in one case, was extracted by the chloroform-free route. PHB was then blended with poly(lactic acid) (PLA) or polycaprolactone (PCL) and plasticized by oligomeric adipate ester (Syncroflex, SN). Tricalcium phosphate (TCP) particles were used as a bioactive filler. Prepared polymer blends were processed into the form of 3D printing filaments. The samples for all the tests performed were prepared by FDM 3D printing or compression molding. Differential scanning calorimetry was conducted to evaluate the thermal properties, followed by optimization of printing temperature by temperature tower test and determination of warping coefficient. Tensile test, three-point flexural test, and compression test were performed to study the mechanical properties of materials. Optical contact angle measurement was conducted to determine the surface properties of these blends and their influence on cell adhesion. Cytotoxicity measurement of prepared blends was conducted to find out whether the prepared materials were non-cytotoxic. The best temperatures for 3D printing were 195/190, 195/175, and 195/165 degrees C for PHB-soap/PLA-SN, PHB/PCL-SN, and PHB/PCL-SN-TCP, respectively. Their mechanical properties (strengths similar to 40 MPa, moduli similar to 2.5 GPa) were comparable with human trabecular bone. The calculated surface energies of all blends were similar to 40 mN/m. Unfortunately, only two out of three materials were proven to be non-cytotoxic (both PHB/PCL blends).