Počet záznamů: 1  

Measuring the muon content of inclined air showers using AERA and the particle detector of the Pierre Auger Observatory

  1. 1.
    0580156 - FZÚ 2024 RIV IT eng C - Konferenční příspěvek (zahraniční konf.)
    Abreu, A. - Aglietta, M. - Allekotte, I. - Gottowik, M. - Bakalová, Alena - Blažek, Jiří - Boháčová, Martina - Chudoba, Jiří - Ebr, Jan - Hamal, Petr - Janeček, Petr - Juryšek, Jakub - Mandát, Dušan - Müller, Ana Laura - Palatka, Miroslav - Pech, Miroslav - Prouza, Michael - Řídký, Jan - dos Santos, Eva M. Martins - Schovánek, Petr - Stadelmaier, Maximilian Klaus - Tobiška, Petr - Trávníček, Petr - Vícha, Jakub - Yushkov, Alexey … celkem 374 autorů
    Measuring the muon content of inclined air showers using AERA and the particle detector of the Pierre Auger Observatory.
    Proceedings of Science. Vol. 424. Trieste: Sissa Medilab srl, 2023, č. článku 049. ISSN 1824-8039.
    [9th International Workshop on Acoustic and Radio EeV Neutrino Detection Activities (ARENA2022). Santiago de Compostela (ES), 07.06.2022-10.06.2022]
    Grant CEP: GA MŠMT LTT18004; GA MŠMT(CZ) EF18_046/0016010; GA MŠMT EF16_013/0001402
    Výzkumná infrastruktura: AUGER-CZ II - 90102
    Institucionální podpora: RVO:68378271
    Klíčová slova: air showers * ultra-high-energy cosmic rays
    Obor OECD: Particles and field physics
    https://pos.sissa.it/424/049/pdf

    A first measurement of the muon content of air showers using hybrid measurements combining radio and particle detection is presented. For inclined air showers with zenith angles above 60°, the water-Cherenkov detector (WCD) of the Pierre Auger Observatory performs an almost pure measurement of the muonic component, whereas the Auger Engineering Radio Array (AERA) allows reconstructing the electromagnetic energy independently using the radio emission of the air shower. The analysis of more than six years of AERA data shows a deficit of muons predicted by all current-generation hadronic interaction models for energies between 4 EeV and 20 EeV. This deficit, already observed in previous analyses of Auger, is now confirmed for the first time with radio data. This analysis is limited by low statistics of only 59 high-quality events due to the small area of AERA of 17 km² and the high energy threshold of 4 EeV originating from the WCD reconstruction.
    Trvalý link: https://hdl.handle.net/11104/0348916

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.