Počet záznamů: 1  

Front face shaping of the inner wall tiles in the COMPASS Upgrade tokamak

  1. 1.
    0578059 - ÚFP 2024 RIV NL eng J - Článek v odborném periodiku
    Gerardin, Jonathan - Balner, Vojtěch - Dejarnac, Renaud - Imríšek, Martin - Jaulmes, Fabien - Komm, Michael - Peterka, Matěj - Vondráček, Petr
    Front face shaping of the inner wall tiles in the COMPASS Upgrade tokamak.
    Fusion Engineering and Design. Roč. 194, September (2023), č. článku 113731. ISSN 0920-3796. E-ISSN 1873-7196
    Grant CEP: GA MŠMT(CZ) EF16_019/0000768
    Institucionální podpora: RVO:61389021
    Klíčová slova: power deposition * divertor * design * Plasma facing components * Field line tracing * Charged particles heat flux * Shaping * Shortwave misalignment
    Obor OECD: Fluids and plasma physics (including surface physics)
    Impakt faktor: 1.7, rok: 2022
    Způsob publikování: Open access
    https://www.sciencedirect.com/science/article/pii/S0920379623003149?via%3Dihub

    The central column of the COMPASS Upgrade tokamak, where the plasma discharges will be started and shut down, is covered by a continuous first wall composed of 8 bulk tungsten guard limiters with recessed Inconel tiles in between. In diverted configurations, the plasma will be limited for a short duration (similar to 0.2 s-0.4 s) during the plasma current ramp-up and ramp-down phases but high heat fluxes due to short power decay lengths are foreseen. An adapted shaping is therefore needed to spread the heat loads over a maximum area. A novel method taking into account the different magnetic equilibria and the incident angle of the field lines was used to design a roof shape able to ensure a constant heat flux on the toroidal direction, accounting for the lambda(gnear-SOL) and lambda(gfar-SOL) Due to the diversity of plasma scenarios considered on COMPASS-U, the optimized shape of the inner wall tiles strongly differs from one scenario to another, thus a compromise has to be found among all foreseen scenarios. The tile shaping also needs to take into account possible short wave misalignments. Calculations with the 3D magnetic field line tracing code PFCFlux validates the design, confirming the constant toroidal profile of deposited heat flux for the COMPASS-U workhorse scenarios, or slightly decreasing or increasing heat flux profiles (from the center to the sides of the tile) for scenarios with smaller or higher lambda(gnear-SOL) respectively, within the expected large range (1.7 mm<lambda(gnear-SOL)<5 mm), but still providing acceptable loads. Estimated heat fluxes are in the range of 5 MW/m(2) to 35 MW/m(2) on the 8 guard limiters, receiving 70%-80% of the power deposited to the inner wall. In case of shortwave misalignments up to 0.5 mm in the radial direction, calculations show that leading edges are still protected, confirming the robustness of the design.
    Trvalý link: https://hdl.handle.net/11104/0347087

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.