Počet záznamů: 1  

A comprehensive study on the thermal and electrical conductivity of EPDM composites with hybrid carbon fillers

  1. 1.
    0574975 - ÚMCH 2024 RIV NL eng J - Článek v odborném periodiku
    Koca, H. D. - Turgut, A. - Evgin, T. - Ates, I. - Chirtoc, M. - Šlouf, Miroslav - Omastová, M.
    A comprehensive study on the thermal and electrical conductivity of EPDM composites with hybrid carbon fillers.
    Diamond and Related Materials. Roč. 139, November (2023), č. článku 110289. ISSN 0925-9635. E-ISSN 1879-0062
    Institucionální podpora: RVO:61389013
    Klíčová slova: polymer composite * thermal conductivity * electrical conductivity
    Obor OECD: Polymer science
    Impakt faktor: 4.1, rok: 2022
    Způsob publikování: Omezený přístup
    https://www.sciencedirect.com/science/article/pii/S0925963523006143?via%3Dihub

    In this study, ethylene-propylene-diene monomer (EPDM) composites reinforced with graphene nanoplatelets (GnPs) and carbon black (CB) fillers and their hybrid combinations of various contents were prepared and examined. The size effect (lateral size and specific surface area) of GnPs and filler hybridization effects between GnPs and CB on the electrical and thermal conductivity of the EPDM composites were examined. The lateral size of GnPs is a more decisive factor in the thermal conductivity of composites than their specific specific surface area, and GnPs with a higher lateral size give better thermal conductivity. The addition of GnPs with a high lateral size and low specific specific surface area results in an almost one-fold increase in thermal conductivity. After a certain filler concentration, a synergistic effect of GnPs and CB on the thermal conductivity can be observed. Up to 20 phr GnPs, the specific surface area or lateral size of GnPs has a slight effect on the electrical conductivity of EPDM/GnPs composites. Higher electrical conductivity was achieved when hybrid fillers, 50 phr CB and 7 phr GnPs with higher lateral size were used for composite preparation. The morphology of the composite samples and the dispersion of all used fillers and hybrids were examined using transmission electron microscopy (TEM) and scanning electron microscopy (SEM).
    Trvalý link: https://hdl.handle.net/11104/0344883

     
     
Počet záznamů: 1  