Počet záznamů: 1
Antimony Hall sensor testing at ITER and DEMO relevant temperatures
- 1.0571916 - ÚFP 2024 RIV NL eng J - Článek v odborném periodiku
Entler, Slavomír - Ďuran, Ivan - Šimonovský, M. - Řeboun, J. - Turjanica, P. - Šobáň, Zbyněk - Sládek, Petr - Viererbl, L.
Antimony Hall sensor testing at ITER and DEMO relevant temperatures.
Fusion Engineering and Design. Roč. 189, April (2023), č. článku 113476. ISSN 0920-3796. E-ISSN 1873-7196
Grant CEP: GA MŠMT(CZ) EF16_019/0000768; GA TA ČR(CZ) TK03030070; GA MŠMT EF16_013/0001405
GRANT EU: European Commission(BE) 101052200
Grant ostatní: AV ČR(CZ) StrategieAV21/27
Program: StrategieAV
Výzkumná infrastruktura: CzechNanoLab - 90110; CzechNanoLab II - 90251
Institucionální podpora: RVO:61389021 ; RVO:68378271
Klíčová slova: Antimony * demo * Hall sensor * iter * Magnetic diagnostics * Steady-state
Obor OECD: Fluids and plasma physics (including surface physics); Condensed matter physics (including formerly solid state physics, supercond.) (FZU-D)
Impakt faktor: 1.7, rok: 2022
Způsob publikování: Omezený přístup
https://www.sciencedirect.com/science/article/pii/S0920379623000601?via%3Dihub
Measurements of the steady-state magnetic field of ITER and DEMO reactors will be performed by Hall sensors that will be part of the magnetic diagnostics. The sensors will contribute to the measurement of the plasma current, plasma-wall clearance, and local perturbations of the magnetic flux surfaces near the wall. The paper describes new ceramic-metal Hall sensors with an antimony sensing layer. The results of temperature tests of second-generation antimony sensors based on thick printed copper technology are presented, including testing of the long-term stability of the sensors.
Trvalý link: https://hdl.handle.net/11104/0342803