Bipolar anodal septal pacing with direct LBB capture preserves physiological ventricular activation better than unipolar left bundle branch pacing

  1. 1.
    0571762 - ÚPT 2024 RIV CH eng J - Článek v odborném periodiku
    Čurila, K. - Jurák, Pavel - Prinzen, F. W. - Jastrzębski, M. - Waldauf, P. - Halámek, Josef - Tóthová, M. - Znojilová, L. - Smíšek, Radovan - Kach, J. - Povišer, L. - Línková, H. - Plešinger, Filip - Moskal, P. - Viščor, Ivo - Vondra, Vlastimil - Leinveber, P. - Osmančík, P.
    Bipolar anodal septal pacing with direct LBB capture preserves physiological ventricular activation better than unipolar left bundle branch pacing.
    Frontiers in Cardiovascular Medicine. Roč. 10, 22 March (2023), č. článku 1140988. E-ISSN 2297-055X
    Grant CEP: GA MZd(CZ) NU21-02-00584
    Institucionální podpora: RVO:68081731
    Klíčová slova: ultra-high-frequency ECG * dyssynchrony * LBBP * anodal septal pacing * His bundle pacing
    Obor OECD: Cardiac and Cardiovascular systems
    Impakt faktor: 3.6, rok: 2022
    Způsob publikování: Open access
    https://www.frontiersin.org/articles/10.3389/fcvm.2023.1140988/full

    Background: Left bundle branch pacing (LBBP) produces delayed, unphysiological activation of the right ventricle. Using ultra-high-frequency electrocardiography (UHF-ECG), we explored how bipolar anodal septal pacing with direct LBB capture (aLBBP) affects the resultant ventricular depolarization pattern. Methods: In patients with bradycardia, His bundle pacing (HBP), unipolar nonselective LBBP (nsLBBP), aLBBP, and right ventricular septal pacing (RVSP) were performed. Timing of local ventricular activation, in leads V1-V8, was displayed using UHF-ECG, and electrical dyssynchrony (e-DYS) was calculated as the difference between the first and last activation. Durations of local depolarizations were determined as the width of the UHF-QRS complex at 50% of its amplitude. Results: aLBBP was feasible in 63 of 75 consecutive patients with successful nsLBBP. aLBBP significantly improved ventricular dyssynchrony (mean9 ms, 95% CI (-12,-6) vs.24 ms (-27,-21), ), p < 0.001) and shortened local depolarization durations in V1-V4 (mean differences7 ms to5 ms (-11,-1), p < 0.05) compared to nsLBBP. aLBBP resulted in e-DYS9 ms (-12,6) vs. e-DYS 10 ms (7,14), p < 0.001 during HBP. Local depolarization durations in V1-V2 during aLBBP were longer than HBP (differences 5-9 ms (1,14), p < 0.05, with local depolarization duration in V1 during aLBBP being the same as during RVSP (difference 2 ms (-2,6), p = 0.52). Conclusion: Although aLBBP improved ventricular synchrony and depolarization duration of the septum and RV compared to unipolar nsLBBP, the resultant ventricular depolarization was still less physiological than during HBP.
    Trvalý link: https://hdl.handle.net/11104/0344481

     
     