Počet záznamů: 1  

Cryopreservation of apheresis platelets treated with riboflavin and UV light

  1. 1.
    0570648 - ÚMCH 2024 RIV GB eng J - Článek v odborném periodiku
    Kutac, D. - Bohonek, M. - Landová, L. - Staskova, E. - Blahutova, M. - Malikova, I. - Šlouf, Miroslav - Horacek, J. M. - Stansbury, L. G. - Hess, J. R. - Seghatchian, J.
    Cryopreservation of apheresis platelets treated with riboflavin and UV light.
    Transfusion and Apheresis Science. Roč. 62, č. 2 (2023), č. článku 103580. ISSN 1473-0502. E-ISSN 1878-1683
    Institucionální podpora: RVO:61389013
    Klíčová slova: cryopreservation * platelets * PRT
    Obor OECD: Polymer science
    Impakt faktor: 1.9, rok: 2022
    Způsob publikování: Omezený přístup
    https://www.sciencedirect.com/science/article/pii/S1473050222002798?via%3Dihub

    Pathogen reduction technology (PRT) is increasingly used in the preparation of platelets for therapeutic transfusion. As the Czech Republic considers PRT, we asked what effects PRT may have on the recovery and function of platelets after cryopreservation (CP), which we use in both military and civilian blood settings. 16 Group O apheresis platelets units were treated with PRT (Mirasol, Terumo BCT, USA) before freezing, 15 similarly collected units were frozen without PRT as controls. All units were processed with 5–6% DMSO, frozen at − 80 °C, stored > 14 days, and reconstituted in thawed AB plasma. After reconstitution, all units were assessed for: platelet count, mean platelet volume (MPV), platelet recovery, thromboelastography, thrombin generation time, endogenous thrombin potential (ETP), glucose, lactate, pH, pO2, pCO2, HCO3, CD41, CD42b, CD62, Annexin V, CCL5, CD62P, and aggregates > 2 mm and selected units for Kunicki score. PRT treated platelet units had lower platelet number (247 vs 278 ×109/U), reduced thromboelastographic MA (38 vs 62 mm) and demonstrated aggregates compared to untreated platelets. Plasma coagulation functions were largely unchanged. Samples from PRT units showed reduced platelet number, reduced function greater than the reduced number would cause, and aggregates. While the platelet numbers are sufficient to meet the European standard, marked platelets activation with weak clot strength suggest reduced effectiveness.
    Trvalý link: https://hdl.handle.net/11104/0342253

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.