Počet záznamů: 1  

Improvement of the signal to noise ratio for fluorescent imaging in microfluidic chips

  1. 1.
    0564731 - BTÚ 2023 RIV DE eng J - Článek v odborném periodiku
    Liu, X. - Zhu, H. - Sabo, Jan - Lánský, Zdeněk - Neuzil, P.
    Improvement of the signal to noise ratio for fluorescent imaging in microfluidic chips.
    Scientific Reports. Roč. 12, č. 1 (2022), č. článku 18911. ISSN 2045-2322. E-ISSN 2045-2322
    Grant CEP: GA MŠMT(CZ) LM2018129; GA MŠMT(CZ) EF18_046/0016045
    Institucionální podpora: RVO:86652036
    Klíčová slova: ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY * SURFACE-ROUGHNESS * X-RAY-FLUORESCENCE
    Obor OECD: 2.10 Nano-technology
    Impakt faktor: 4.6, rok: 2022
    Způsob publikování: Open access
    https://www.nature.com/articles/s41598-022-23426-z

    Microfluidics systems can be fabricated in various ways using original silicon glass systems, with easy Si processing and surface modifications for subsequent applications such as cell seeding and their study. Fluorescent imaging of cells became a standard technique for the investigation of cell behavior. Unfortunately, high sensitivity fluorescent imaging, e.g., using total internal reflection fluorescence (TIRF) microscopy, is problematic in these microfluidic systems because the uneven surfaces of the silicon channels' bottoms affect light penetration through the optical filters. In this work, we study the nature of the phenomenon, finding that the problem can be rectified by using a silicon-on-insulator (SOI) substrate, defining the channel depth by the thickness of the top Si layer, and halting the etching at the buried SiO2 layer. Then the fluorescent background signal drops by = 5 times, corresponding to the limit of detection drop from = 0.05 mM to = 50 nM of fluorescein. We demonstrate the importance of a flat surface using TIRF-based single-molecule detection, improving the signal to a noise ratio more than 18 times compared to a conventional Si wafer. Overall, using very high-quality SOI substrates pays off, as it improves the fluorescence image quality due to the increase in signal-to-noise ratio. Concerning the cost of microfluidic device fabrication-design, mask fabrication, wafer processing, and device testing-the initial SOI wafer cost is marginal, and using it improves the system performance.
    Trvalý link: https://hdl.handle.net/11104/0337886

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.