Preparativeseparationof immunoglobulins from bovine colostrum by continuous divergent-flow electrophoresis

  1. 1.
    0562904 - ÚIACH 2024 RIV DE eng J - Článek v odborném periodiku
    Šťastná, Miroslava - Šlais, Karel
    Preparativeseparationof immunoglobulins from bovine colostrum by continuous divergent-flow electrophoresis.
    Journal of Separation Science. Roč. 46, č. 1 (2023), č. článku 2200679. ISSN 1615-9306. E-ISSN 1615-9314
    Institucionální podpora: RVO:68081715
    Klíčová slova: continuous flow preparation * isotachophoresis * moving boundary electrophoresis
    Obor OECD: Analytical chemistry
    Impakt faktor: 3.1, rok: 2022
    Způsob publikování: Omezený přístup

    Immunoglobulins in bovine colostrum were separated and fractionated from other proteins using method and instrumentation developed in our laboratory. The proposed separation was based on bidirectional isotachophoresis/moving boundary electrophoresis with electrofocusing of the analytes in pH gradient from 3.9 to 10.1. The preparative instrumentation included the trapezoidal non-woven fabric that served as separation space with divergent continuous flow. The defatted and casein precipitate free colostrum supernatant was loaded directly into instrument without any additional colostrum pre-preparation. Immunoglobulin G that was fractionated from other immune proteins such as bovine serum albumin, β-lactoglobulin and α-lactalbumin, was continuously collected in separated fractions over 3 hours. The fractions were further processed, and isolated immunoglobulin G in the liquid fractions was confirmed by sodium dodecyl sulphate-polyacrylamide gel electrophoresis and by re-focusing in gel isoelectric focusing. Separated immunoglobulin G was detected in seven fractions by sodium dodecyl sulphate-polyacrylamide gel electrophoresis with gradually decreased concentration in the fractions. Re-focusing of the proteins in the fractions by gel isoelectric focusing revealed multiple separated zones of immunoglobulin G with the pI values covering the range from 5.4 to 7.2. Each fraction contained the distinct zones with gradually increased pI values and decreased concentrations from fraction to fraction.
    Trvalý link: https://hdl.handle.net/11104/0335073

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0562904.pdf19.7 MBVydavatelský postprintvyžádat
    0562904.pdf2698.9 KBAutorský preprintvyžádat
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.