Počet záznamů: 1  

Selective potentiometric detection of reactive oxygen species (ROS) in biologically relevant concentrations by a modified metalized polyporphyrine sensing layer coated with nonbiofouling poly(2-alkyl-2oxazoline)s

  1. 1.
    0556452 - ÚMCH 2023 RIV CH eng J - Článek v odborném periodiku
    Urbánek, Tomáš - Ivanko, Iryna - Svoboda, Jan - Tomšík, Elena - Hrubý, Martin
    Selective potentiometric detection of reactive oxygen species (ROS) in biologically relevant concentrations by a modified metalized polyporphyrine sensing layer coated with nonbiofouling poly(2-alkyl-2oxazoline)s.
    Sensors and Actuators B - Chemical. Roč. 363, 15 July (2022), č. článku 131827. E-ISSN 0925-4005
    Grant CEP: GA ČR(CZ) GA21-01090S; GA MZd(CZ) NU20-06-00424
    Institucionální podpora: RVO:61389013
    Klíčová slova: ROS * polyporphyrine * nonbiofouling
    Obor OECD: Polymer science
    Impakt faktor: 8.4, rok: 2022
    Způsob publikování: Omezený přístup
    https://www.sciencedirect.com/science/article/pii/S0925400522004695?via%3Dihub

    We built a robust selective potentiometric sensor of reactive oxygen species (ROS) as a thin layer applied on the surface of smart implants, which enables the detection and localization of inflammation at an early stage. The sensor consists of a conductive polymer layer based on polythiophene with an incorporated porphyrin-metal complex that potentiometrically detects the presence of ROS. This sensor is covalently coated with a nonbiofouling layer of poly(2-methyl-2-oxazoline), which works as a biocompatibilizer but mainly prevents the sorption of proteins and other biomacromolecules naturally occurring in organisms, which could interfere with the ROS signal. We have shown that our potentiometric sensor shows a rapid response to hydrogen peroxide, does not experience interference with bovine serum albumin as a model serum protein when sensing ROS, is able to fully reversibly detect ROS with a linear response within a very wide range of biologically relevant concentrations and, most importantly, is able to distinguish between hydrogen peroxide and hypochlorite. We also performed a head-to-head comparison of two positional isomers of thienylated porphyrine for sensor applications (2TTP and 3TTP, with 3TTP shown to be more appropriate) and four different coordinated metals (Cu, Fe, Co and Mn, with Cu and especially Fe shown to be the most appropriate).
    Trvalý link: http://hdl.handle.net/11104/0330870

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.