Počet záznamů: 1  

Continental Thunderstorm Ground Enhancement observed at an exceptionally low altitude

  1. 1.
    0556323 - ÚFA 2023 RIV DE eng J - Článek v odborném periodiku
    Kolmašová, Ivana - Santolík, Ondřej - Šlegl, Jakub - Popová, Jana - Sokol, Zbyněk - Zacharov, Petr, jr. - Ploc, Ondřej - Diendorfer, G. - Langer, Ronald - Lán, Radek - Strhárský, I.
    Continental Thunderstorm Ground Enhancement observed at an exceptionally low altitude.
    Atmospheric Chemistry and Physics. Roč. 22, č. 12 (2022), s. 7959-7973. ISSN 1680-7316. E-ISSN 1680-7324
    Grant CEP: GA ČR GA20-09671S; GA MŠMT EF15_003/0000481
    Institucionální podpora: RVO:68378289 ; RVO:61389005
    Klíčová slova: Gamma Ray * Lightning * Hydrometeors
    Obor OECD: Fluids and plasma physics (including surface physics); Meteorology and atmospheric sciences (UJF-V)
    Impakt faktor: 6.3, rok: 2022
    Způsob publikování: Open access
    https://acp.copernicus.org/articles/22/7959/2022/

    Two long-lasting Thunderstorm Ground Enhancement (TGE) events were registered at the Milešovka meteorological observatory in Czechia (50.55N, 13.93E, altitude 837 m) on 23 April 2018, during linearly organized thunderstorms. Two intervals of increased photon counts were detected by a plastic scintillator, respectively lasting 70 and 25 minutes, and reaching 31 % and 48 % above the background radiation levels. Using numerical simulations, we verified that the observed increases of count rates are consistent with the energy spectrum of previously observed TGEs. We investigated the relevant data from a suite of meteorological instruments, a Ka-band cloud radar, an electric field mill, and a broadband electromagnetic receiver, all placed at the Milešovka observatory, in order to analyze the context in which these unique continental TGEs occurred at an exceptionally low altitude. The onset of the TGEs preceded the onset of precipitation by 10 and 3 minutes, respectively, for the two events. Both this delayed rain arrival and a lower energy threshold of 6.5 MeV for registered particles clearly exclude the detection the decay products of the radon progeny washout during the TGE intervals. At the same time, the European lightning detection network EUCLID detected numerous predominantly negative intracloud lightning discharges at distances closer than 5 km from the particle detector, while the occurrence of cloud-to-ground discharges was suppressed. The cloud radar recorded presence of graupel below the melting level and the composition of hydrometeors suggested good conditions for cloud electrification. The observed variations of the near surface electric field were unusual, with very brief negative electric field excursions reaching -20 kV in a quick succession. At the same time, sub-microsecond unipolar pulses emitted by close corona discharges saturated the broadband magnetic loop antenna. All these measurements indicate that a strong lower positive charge region was present inside the thundercloud. The bottom thundercloud dipole was probably responsible for acceleration of the seed electrons in the air. These seed electrons might originate not only in the secondary cosmic ray particles but could also come from a high concentration of radon in the air collected during the propagation of the convective system above the uranium-rich soils before the thunderstorms overpassed the Milešovka observatory.
    Trvalý link: http://hdl.handle.net/11104/0330612

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0556323_AtmosChemPhys_Kolmašová_2022.pdf16.8 MBVydavatelský postprintvyžádat
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.