Počet záznamů: 1
Complement activation dramatically accelerates blood plasma fouling on antifouling poly(2-hydroxyethyl methacrylate) brush surfaces
- 1.0555739 - ÚMCH 2023 RIV DE eng J - Článek v odborném periodiku
Riedel, Tomáš - de los Santos Pereira, Andres - Táborská, Johanka - Riedelová, Zuzana - Pop-Georgievski, Ognen - Májek, P. - Pečánková, K. - Rodriguez-Emmenegger, C.
Complement activation dramatically accelerates blood plasma fouling on antifouling poly(2-hydroxyethyl methacrylate) brush surfaces.
Macromolecular Bioscience. Roč. 22, č. 3 (2022), č. článku 2100460. ISSN 1616-5187. E-ISSN 1616-5195
Grant CEP: GA ČR(CZ) GA20-10845S
Grant ostatní: AV ČR(CZ) MSM200502001
Program: Program na podporu mezinárodní spolupráce začínajících výzkumných pracovníků
Institucionální podpora: RVO:61389013
Klíčová slova: antifouling coatings * complement C3 * polymer brushes
Obor OECD: Biophysics
Impakt faktor: 4.6, rok: 2022
Způsob publikování: Omezený přístup
https://onlinelibrary.wiley.com/doi/10.1002/mabi.202100460
Non-specific protein adsorption (fouling) triggers a number of deleterious events in the application of biomaterials. Antifouling polymer brushes successfully suppress fouling, however for some coatings an extremely high variability of fouling for different donors remains unexplained. The authors report that in the case of poly(2-hydroxyethyl methacrylate) (poly(HEMA)) this variability is due to the complement system activation that causes massive acceleration in the fouling kinetics of blood plasma. Using plasma from various donors, the fouling kinetics on poly(HEMA) is analyzed and correlated with proteins identified in the deposits on the surface and with the biochemical compositions of the plasma. The presence of complement components in fouling deposits and concentrations of C3a in different plasmas indicate that the alternative complement pathway plays a significant role in the fouling on poly(HEMA) through the “tick-over” mechanism of spontaneous C3 activation. The generated C3b binds to the poly(HEMA) surface and amplifies complement activation locally. Heat-inactivated plasma prevents accelerated fouling kinetics, confirming the central role of complement activation. The results highlight the need to take into account the variability between individuals when assessing interactions between biomaterials and blood plasma, as well as the importance of the mechanistic insight that can be gained from protein identification.
Trvalý link: http://hdl.handle.net/11104/0330403
Počet záznamů: 1