Počet záznamů: 1  

Fast 4D on-the-fly tomography for observation of advanced pore morphology (APM) foam elements subjected to compressive loading

  1. 1.
    0548910 - ÚTAM 2022 RIV CH eng J - Článek v odborném periodiku
    Vopálenský, Michal - Koudelka_ml., Petr - Šleichrt, Jan - Kumpová, Ivana - Borovinsek, M. - Vesenjak, M. - Kytýř, Daniel
    Fast 4D on-the-fly tomography for observation of advanced pore morphology (APM) foam elements subjected to compressive loading.
    Materials. Roč. 14, č. 23 (2021), č. článku 7256. E-ISSN 1996-1944
    Grant CEP: GA MŠMT(CZ) EF16_019/0000766
    Institucionální podpora: RVO:68378297
    Klíčová slova: 4D CT * advanced pore morphology (APM) foam * compressive loading * image quality * in-situ mechanical testing * microcomputed tomography * on-the-fly tomography
    Obor OECD: Materials engineering
    Impakt faktor: 3.748, rok: 2021
    Způsob publikování: Open access
    https://doi.org/10.3390/ma14237256

    Observation of dynamic testing by means of X-ray computed tomography (CT) and in-situ loading devices has proven its importance in material analysis already, yielding detailed 3D information on the internal structure of the object of interest and its changes during the experiment. However, the acquisition of the tomographic projections is, in general, a time-consuming task. The standard method for such experiments is the time-lapse CT, where the loading is suspended for the CT scan. On the other hand, modern X-ray tubes and detectors allow for shorter exposure times with an acceptable image quality. Consequently, the experiment can be designed in a way so that the mechanical test is running continuously, as well as the rotational platform, and the radiographic projections are taken one after another in a fast, free-running mode. Performing this so-called on-the-fly CT, the time for the experiment can be reduced substantially, compared to the time-lapse CT. In this paper, the advanced pore morphology (APM) foam elements were used as the test objects for in-situ X-ray microtomography experiments, during which series of CT scans were acquired, each with the duration of 12 s. The contrast-to-noise ratio and the full-width-half-maximum parameters are used for the quality assessment of the resultant 3D models. A comparison to the 3D models obtained by time-lapse CT is provided.
    Trvalý link: http://hdl.handle.net/11104/0324953

     
     