Počet záznamů: 1  

Oxidation of antibiotics by ferrate(VI) in water: Evaluation of their removal efficiency and toxicity changes

  1. 1.
    0547319 - BÚ 2022 RIV GB eng J - Článek v odborném periodiku
    Kovaláková, Pavla - Cizmas, L. - Feng, M. - McDonald, T. J. - Maršálek, Blahoslav - Sharma, V. K.
    Oxidation of antibiotics by ferrate(VI) in water: Evaluation of their removal efficiency and toxicity changes.
    Chemosphere. Roč. 277, AUG 2021 (2021), č. článku 130365. ISSN 0045-6535. E-ISSN 1879-1298
    Grant CEP: GA TA ČR SS01020006
    Institucionální podpora: RVO:67985939
    Klíčová slova: ecotoxicity * algae * cyanobacteria * antibiotics * ferrate
    Obor OECD: Ecology
    Impakt faktor: 8.943, rok: 2021
    Způsob publikování: Open access s časovým embargem
    https://doi.org/10.1016/j.chemosphere.2021.130365

    Antibiotics in water and wastewater have been determined extensively. The treatment of antibiotics in water needs evaluation of possible harmful effects on aquatic ecosystems and human health. This paper presents the toxicity evaluation of antibiotics after their treatment with ferrate (VI) ((FeO42-)-O-VI, Fe(VI)) in water. The antibiotics (sulfamethoxazole (SMX), erythromycin (ERY), ofloxacin (OFL), ciprofloxacin (CIP), tetracycline (TET), oxytetracycline (OXY), and trimethoprim (TMP)) were treated at pH 8.0 by applying two concentrations of Fe(VI) to have molar ratios of 5:1 and 10:1 ([Fe(VI)]:[antibiotic]). Under the studied conditions, incomplete removal of antibiotics was observed, suggesting that the treated solutions contained parent antibiotics and their transformation products. The toxicity of antibiotics without Fe(VI) treatment was tested against freshwater green alga Raphidocelis subcapitata and cyanobacterium Synechococcus elongatus, which were determined to be generally sensitive to antibiotics, with EC50 < 1.0 mg/L. The toxicity of Fe(VI) treated solution was tested against R. subcapitata. Results found no toxicity for the treated solutions of OFL, CIP, and OXY. However, SMX, ERY, and TET remained toxic after Fe(VI) treatment (i.e., more than 75% growth inhibition of R. subcapitata). Results demonstrated that R. subcapitata may be applied to test the toxicity of antibiotics after oxidative treatments.
    Trvalý link: http://hdl.handle.net/11104/0325108

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    Oxidation of antibiotics by ferrate.pdf01.3 MBJinápovolen
     
Počet záznamů: 1  