Počet záznamů: 1  

A multipurpose end-station for atomic, molecular and optical sciences and coherent diffractive imaging at ELI beamlines

  1. 1.
    0546958 - FZÚ 2022 RIV DE eng J - Článek v odborném periodiku
    Klimešová, Eva - Kulyk, Olena - Hoque, Ziaul - Roos, Andreas Hult - Khakurel, Krishna - Rebarz, Mateusz - Jurkovič, Matěj - Albrecht, Martin - Finke, Ondřej - Lera, Roberto - Hort, Ondřej - Mai, Dong-Du - Nejdl, Jaroslav - Sokol, Martin - Fink, Rasmus Burlund - Ben Ltaief, L. - Westphal, D. - Wolf, Adam - Laštovička, Tomáš - Frassetto, F. - Poletto, L. - Andreasson, Jakob - Krikunova, Maria
    A multipurpose end-station for atomic, molecular and optical sciences and coherent diffractive imaging at ELI beamlines.
    European Physical Journal-Special Topics. Roč. 230, č. 23 (2021), s. 4183-4194. ISSN 1951-6355. E-ISSN 1951-6401
    Grant CEP: GA MŠMT(CZ) LM2018141; GA MŠMT EF16_019/0000789; GA MŠMT EF15_003/0000447
    Grant ostatní: OP VVV - ADONIS(XE) CZ.02.1.01/0.0/0.0/16_019/0000789; OP VVV - ELIBIO(XE) CZ.02.1.01/0.0/0.0/15_003/0000447
    Výzkumná infrastruktura: ELI Beamlines III - 90141
    Institucionální podpora: RVO:68378271
    Klíčová slova: extreme-ultraviolet * electronic-structure * photoelectron * generation * dynamics * pulses * spectroscopy * gas * nanoparticles * ionization
    Obor OECD: Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
    Impakt faktor: 2.891, rok: 2021
    Způsob publikování: Open access

    We report on the status of a users’ end-station, MAC: a Multipurpose station for Atomic, molec ular and optical sciences and Coherent diffractive imaging, designed for studies of structure and dynamics of matter in the femtosecond time-domain. MAC is located in the E1 experimental hall on the high har monic generation (HHG) beamline of the ELI Beamlines facility. The extreme ultraviolet beam from the HHG beamline can be used at the MAC end-station together with a synchronized pump beam (which will cover the NIR/Vis/UV or THz range) for time-resolved experiments on different samples. Sample delivery systems at the MAC end-station include a molecular beam, a source for pure or doped clusters, ultrathin cylindrical or flat liquid jets, and focused beams of substrate-free nanoparticles produced by an electrospray or a gas dynamic virtual nozzle combined with an aerodynamic lens stack.
    Trvalý link: http://hdl.handle.net/11104/0326795

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0546958.pdf45.1 MBCC licenceVydavatelský postprintpovolen
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.