Počet záznamů: 1
Hydrogen-terminated diamond surface as a gas sensor: a comparative study of its sensitivities
- 1.0546561 - FZÚ 2022 RIV CH eng J - Článek v odborném periodiku
Kočí, Michal - Kromka, Alexander - Bouřa, A. - Szabó, Ondrej - Husák, M.
Hydrogen-terminated diamond surface as a gas sensor: a comparative study of its sensitivities.
Sensors. Roč. 21, č. 16 (2021), č. článku 5390. ISSN 1424-8220. E-ISSN 1424-8220
Grant CEP: GA MŠMT(CZ) EF16_019/0000760; GA MŠMT LM2018110
Grant ostatní: OP VVV - SOLID21(XE) CZ.02.1.01/0.0/0.0/16_019/0000760; AV ČR(CZ) SAV-21-10
Program: Bilaterální spolupráce
Institucionální podpora: RVO:68378271
Klíčová slova: nanocrystalline diamond (NCD) * metal oxide (MOX) * gas detectors
Obor OECD: Materials engineering
Impakt faktor: 3.847, rok: 2021 ; AIS: 0.586, rok: 2021
Způsob publikování: Open access
DOI: https://doi.org/10.3390/s21165390
A nanocrystalline diamond (NCD) layer is used as an active (sensing) part of a conductivity gas sensor. The properties of the sensor with an NCD with H-termination (response and time characteristic of resistance change) are measured by the same equipment with a similar setup and compared with commercial sensors, a conductivity sensor with a metal oxide (MOX) active material (resistance change), and an infrared pyroelectric sensor (output voltage change) in this study. The deposited layer structure is characterized and analyzed by Scanning Electron Microscopy (SEM) and Raman spectroscopy. Electrical properties (resistance change for conductivity sensors and output voltage change for the IR pyroelectric sensor) are examined for two types of gases, oxidizing (NO2) and reducing (NH3). The parameters of the tested sensors are compared and critically evaluated. Subsequently, differences in the gas sensing principles of these conductivity sensors are described.
Trvalý link: http://hdl.handle.net/11104/0323198
Název souboru Staženo Velikost Komentář Verze Přístup 0546561.pdf 2 6.5 MB CC Licence Vydavatelský postprint povolen