In vivo macromolecule signals in rat brain 1H-MR spectra at 9.4T: Parametrization, spline baseline estimation, and T2 relaxation times

  1. 1.
    0544062 - ÚPT 2022 RIV US eng J - Článek v odborném periodiku
    Simicic, D. - Rackayová, V. - Xin, L. - Tkáč, I. - Borbath, T. - Starčuk jr., Zenon - Starčuková, Jana - Lanz, B. - Cudalbu, C.
    In vivo macromolecule signals in rat brain 1H-MR spectra at 9.4T: Parametrization, spline baseline estimation, and T2 relaxation times.
    Magnetic Resonance in Medicine. Roč. 86, č. 5 (2021), s. 2384-2401. ISSN 0740-3194. E-ISSN 1522-2594
    Grant CEP: GA MŠMT(CZ) EF16_013/0001775
    Institucionální podpora: RVO:68081731
    Klíčová slova: 1H-MRS * baseline * fitting * macromolecules * parametrization * rat brain * relaxation times * UHF
    Obor OECD: Medical engineering
    Impakt faktor: 3.737, rok: 2021
    Způsob publikování: Open access
    https://onlinelibrary.wiley.com/doi/10.1002/mrm.28910

    Purpose: Reliable detection and fitting of macromolecules (MM) are crucial for accurate quantification of brain short-echo time (TE) 1H-MR spectra. An experimentally acquired single MM spectrum is commonly used. Higher spectral resolution at ultra-high field (UHF) led to increased interest in using a parametrized MM spectrum together with flexible spline baselines to address unpredicted spectroscopic components. Herein, we aimed to: (1) implement an advanced methodological approach for post-processing, fitting, and parametrization of 9.4T rat brain MM spectra, (2) assess the concomitant impact of the LCModel baseline and MM model (ie, single vs parametrized), and (3) estimate the apparent T2 relaxation times for seven MM components.
    Methods: A single inversion recovery sequence combined with advanced AMARES prior knowledge was used to eliminate the metabolite residuals, fit, and parametrize 10 MM components directly from 9.4T rat brain in vivo 1H-MR spectra at different TEs. Monte Carlo simulations were also used to assess the concomitant influence of parametrized MM and DKNTMN parameter in LCModel.
    Results: A very stiff baseline (DKNTMN ≥ 1 ppm) in combination with a single MM spectrum led to deviations in metabolite concentrations. For some metabolites the parametrized MM showed deviations from the ground truth for all DKNTMN values. Adding prior knowledge on parametrized MM improved MM and metabolite quantification. The apparent T2 ranged between 12 and 24 ms for seven MM peaks.
    Conclusion: Moderate flexibility in the spline baseline was required for reliable quantification of real/experimental spectra based on in vivo and Monte Carlo data. Prior knowledge on parametrized MM improved MM and metabolite quantification.