Počet záznamů: 1  

Ceramic‐chromium hall sensors for environments with high temperatures and neutron radiation

  1. 1.
    0543097 - ÚFP 2022 RIV CH eng J - Článek v odborném periodiku
    Entler, Slavomír - Šobáň, Zbyněk - Ďuran, Ivan - Kovařík, Karel - Výborný, Karel - Šebek, Josef - Tazlaru, S. - Střeleček, J. - Sládek, Petr
    Ceramic‐chromium hall sensors for environments with high temperatures and neutron radiation.
    Sensors. Roč. 21, č. 3 (2021), s. 1-12, č. článku 721. E-ISSN 1424-8220
    Grant CEP: GA MŠMT(CZ) 8D15001; GA MŠMT(CZ) EF16_019/0000768; GA MŠMT LM2018110
    GRANT EU: European Commission(XE) 633053 - EUROfusion
    Institucionální podpora: RVO:61389021 ; RVO:68378271
    Klíčová slova: Chromium * demo * Fusion * Hall sensors * High temperature * Metal * Nanolayer * Nu-clear * Radiation * Resistant
    Obor OECD: Fluids and plasma physics (including surface physics); Fluids and plasma physics (including surface physics) (FZU-D)
    Impakt faktor: 3.847, rok: 2021
    Způsob publikování: Open access
    https://www.mdpi.com/1424-8220/21/3/721

    Ceramic‐chromium Hall sensors represent a temperature and radiation resistant alternative to Hall sensors based on semiconductors. Demand for these sensors is presently motivated by the ITER and DEMO nuclear fusion projects. The developed ceramic‐chromium Hall sensors were tested up to a temperature of 550 °C and a magnetic field of 14 T. The magnitude of the sensitivity of the tested sensor was 6.2 mV/A/T at 20 °C and 4.6 mV/A/T at 500 °C. The sensitivity was observed to be weakly dependent on a temperature above 240 °C with an average temperature coefficient of 0.014%/°C and independent of the magnetic field with a relative average deviation below the measurement accuracy of 0.086%. A simulation of a neutron‐induced transmutation was performed to assess changes in the composition of the chromium. After 5.2 operational years of the DEMO fusion reactor, the transmuted fraction of the chromium sensitive layer was found to be 0.27% at the most exposed sensor location behind the divertor cassette with a neutron fluence of 6.08 × 10 n/m . The ceramic‐chromium Hall sensors show the potential to be suitable magnetic sensors for environments with high temperatures and strong neutron radiation. 25 2
    Trvalý link: http://hdl.handle.net/11104/0320386

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.