Počet záznamů: 1
A comparison of LIDT behavior of AR-coated yttrium-aluminium-garnet substrates with respect to thin-film design and coating technology
- 1.0542382 - FZÚ 2022 RIV US eng C - Konferenční příspěvek (zahraniční konf.)
Uxa, Š. - Škoda, V. - Vanda, Jan - Muresan, Mihai-George
A comparison of LIDT behavior of AR-coated yttrium-aluminium-garnet substrates with respect to thin-film design and coating technology.
Laser-Induced Damage in Optical Materials. Bellingham: SPIE, 2018 - (Carr, C.; Exarhos, G.; Soileau, M.), č. článku 108051R. Proceedings of SPIE, 10805. ISBN 978-1-510-62194-7. ISSN 0277-786X.
[Annual Laser Damage Symposium /50./. Boulder (US), 23.09.2018-26.09.2018]
Grant CEP: GA TA ČR TH02010579
Institucionální podpora: RVO:68378271
Klíčová slova: coating * polishing * YAG lasers * thin films * laser damage threshold * thin film coatings * ntireflective coatings
Obor OECD: Optics (including laser optics and quantum optics)
https://www.spiedigitallibrary.org/conference-proceedings-of-spie/10805/2500189/A-comparison-of-LIDT-behavior-of-AR-coated-yttrium-aluminium/10.1117/12.2500189.short
Several sets of polished substrates were manufactured from monocrystalline yttrium-aluminium-garnet (YAG) grown by the Czochralski method. Samples were coated by both narrow-band and broad-band dielectric anti-reflection (AR) thin-film system prepared using either reactive or ion-assisted e-beam deposition technology and tested for laser-induced damage threshold (LIDT) at 1030 nm 10 ns in s-on-1 mode according to the ISO 21254 standard. Measured damage thresholds at normal (0 deg) incidence were compared for different thin-film designs and coating technology.
Trvalý link: http://hdl.handle.net/11104/0319805