Počet záznamů: 1  

FDM 3D Printed Composites for Bone Tissue Engineering Based on Plasticized Poly(3-hydroxybutyrate)/poly(d,l-lactide) Blends

  1. 1.
    0539759 - ÚEM 2021 RIV CH eng J - Článek v odborném periodiku
    Melčová, M. - Svoradová, K. - Menčík, P. - Kontárová, S. - Rampichová, Michala - Hedvičáková, Věra - Sovková, Věra - Přikryl, R. - Vojtová, L.
    FDM 3D Printed Composites for Bone Tissue Engineering Based on Plasticized Poly(3-hydroxybutyrate)/poly(d,l-lactide) Blends.
    Polymers. Roč. 12, č. 12 (2020), č. článku 2806. E-ISSN 2073-4360
    Grant CEP: GA ČR(CZ) GA18-09306S
    Institucionální podpora: RVO:68378041
    Klíčová slova: additive manufacturing * fused deposition modeling * poly(3-hydroxybutyrate)
    Obor OECD: Biomaterials (as related to medical implants, devices, sensors)
    Impakt faktor: 4.329, rok: 2020
    Způsob publikování: Open access
    https://www.mdpi.com/2073-4360/12/12/2806

    Tissue engineering is a current trend in the regenerative medicine putting pressure on scientists to develop highly functional materials and methods for scaffolds' preparation. In this paper, the calibrated filaments for Fused Deposition Modeling (FDM) based on plasticized poly(3-hydroxybutyrate)/poly(d,l-lactide) 70/30 blend modified with tricalcium phosphate bioceramics were prepared. Two different plasticizers, Citroflex (n-Butyryl tri-n-hexyl citrate) and Syncroflex (oligomeric adipate ester), both used in the amount of 12 wt%, were compared. The printing parameters for these materials were optimized and the printability was evaluated by recently published warping test. The samples were studied with respect to their thermal and mechanical properties, followed by biological in vitro tests including proliferation, viability, and osteogenic differentiation of human mesenchymal stem cells. According to the results from differential scanning calorimetry and tensile measurements, the Citroflex-based plasticizer showed very good softening effect at the expense of worse printability and unsatisfactory performance during biological testing. On the other hand, the samples with Syncroflex demonstrated lower warping tendency compared to commercial polylactide filament with the warping coefficient one third lower. Moreover, the Syncroflex-based samples exhibited the non-cytotoxicity and promising biocompatibility.
    Trvalý link: http://hdl.handle.net/11104/0317457

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.