Počet záznamů: 1  

Tellurium determination by three modes of instrumental neutron activation analysis in aerosol filters and trap solutions for the simulation of a severe nuclear accident

  1. 1.
    0534030 - ÚJF 2021 RIV NL eng J - Článek v odborném periodiku
    Kučera, Jan - Pasi, A-E. - Espergen, F. - Karkela, T. - Lerum, H. V. - Omtvedt, J. P. - Ekberg, C.
    Tellurium determination by three modes of instrumental neutron activation analysis in aerosol filters and trap solutions for the simulation of a severe nuclear accident.
    Microchemical Journal. Roč. 158, NOV (2020), č. článku 105139. ISSN 0026-265X. E-ISSN 1095-9149
    Grant CEP: GA MŠMT LM2015056
    Výzkumná infrastruktura: Reactors LVR-15 and LR-0 II - 90120
    Institucionální podpora: RVO:61389005
    Klíčová slova: 132Te fission product * instrumental neutron activation analysis * self-verification principle * severe nuclear accident * Te determination
    Obor OECD: Analytical chemistry
    Impakt faktor: 4.821, rok: 2020
    Způsob publikování: Omezený přístup
    https://doi.org/10.1016/j.microc.2020.105139

    Tellurium belongs to the elements not frequently determined by neutron activation analysis (NAA) or other analytical methods. We present results of a new methodological study using three independent modes of instrumental NAA (INAA) using the Te-123m, Te-131 and T-131 radionuclides. We compare the results obtained in terms of accuracy, precision and limits of detection (LOD). We utilized the INAA procedures tested for the tellurium determination in aerosol filters and trap solutions in a model experiment aimed at reducing the knowledge gap concerning the behaviour of Te-132, a radiologically significant fission product, which constitutes a considerable health risk towards the public in case of its release in a severe nuclear power plant accident. We found that the nuclear reaction Te-130(n,gamma)Te-131 and gamma-ray spectrometric measurement of I-131, a descendant of Te-131, is the most sensitive way of Te determination by INAA providing as low LOD values as 0.15 mu g of Te in the Teflon aerosol filters and 0.22 mu g mL(-1) in the 0.1 M NaOH trap solutions. The three independent INAA modes allowed employing the self-verification principle of INAA for increasing the trustworthiness of our results. Finally, we also point to the indispensable role of the non-destructive feature of INAA for assay of samples, such as Teflon aerosol filters, that are difficult to be analysed by other analytical methods requiring complete sample destruction without analyte losses.
    Trvalý link: http://hdl.handle.net/11104/0312247

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.