Počet záznamů: 1  

LIBS analysis of samples from the COMPASS vacuum chamber after liquid metal experiments – Li campaign

  1. 1.
    0533925 - ÚFP 2021 RIV US eng J - Článek v odborném periodiku
    Veis, P. - Atikkuke, S. - Marin Roldan, A. - Dwivedi, V. - Veis, M. - Bartoň, Petr - Jeřáb, Martin - Dejarnac, Renaud
    LIBS analysis of samples from the COMPASS vacuum chamber after liquid metal experiments – Li campaign.
    Nuclear Materials and Energy. Roč. 25, December (2020), č. článku 100809. E-ISSN 2352-1791
    Grant CEP: GA MŠMT(CZ) LM2018117; GA MŠMT(CZ) EF16_019/0000768
    GRANT EU: European Commission(XE) 633053 - EUROfusion
    Institucionální podpora: RVO:61389021
    Klíčová slova: compass * Li * libs * Liquid metals * Plasma-facing materials * Tokamak
    Obor OECD: Fluids and plasma physics (including surface physics)
    Impakt faktor: 2.320, rok: 2020
    Způsob publikování: Open access
    https://www.sciencedirect.com/science/article/pii/S2352179120300843?via%3Dihub

    To overcome the erosion of the plasma-facing materials (PFMs) inside a fusion reactor, liquid metals such as lithium or tin are being explored as potential PFMs in fusion reactors due to their several advantages such as self-repair or high-power exhaust capability. Lithium can reduce the oxygen and carbon impurity contamination by chemically binding these species to the wall. Thus, experiments of power handling performance with a special liquid metal (Li) divertor module based on the capillary porous system technology were performed in the tokamak COMPASS. The elemental analysis of 14 screw samples located around the vacuum vessel provides information about the migration of evaporated/redeposited liquid elements. The main goal of this work is to characterize and quantify screws containing Li-based coating by LIBS by measuring the quantitative elemental composition. The studied samples were Li-coated Ni-Cr-based screws. The laser ablation was performed in air at atmospheric pressure using a 5 ns pulse Nd:YAG laser at 1064 nm. Suitable Li I, Ca I-II, and Fe I spectral lines were employed for the evaluation of the electron temperature of the plasma using multi-elemental Saha-Boltzmann plots. The electron density was obtained from the Stark broadening of the Hα spectral line. The elemental content of each sample was then obtained by calibration-free LIBS (CF-LIBS).
    Trvalý link: http://hdl.handle.net/11104/0312154

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.