Počet záznamů: 1  

5-Nitro-2,4-Dichloropyrimidine as an Universal Model for Low-Energy Electron Processes Relevant for Radiosensitization

  1. 1.
    0533836 - ÚFCH JH 2021 RIV CH eng J - Článek v odborném periodiku
    Luxford, Thomas Frederick Murray - Pshenichnyuk, S. A. - Asfandiarov, N. L. - Perečko, Tomáš - Falk, Martin - Kočišek, Jaroslav
    5-Nitro-2,4-Dichloropyrimidine as an Universal Model for Low-Energy Electron Processes Relevant for Radiosensitization.
    International Journal of Molecular Sciences. Roč. 21, č. 21 (2020), č. článku 8173. E-ISSN 1422-0067
    Grant CEP: GA ČR GJ16-10995Y; GA ČR(CZ) GJ17-08066Y; GA ČR(CZ) GA19-09212S; GA MŠMT EF16_026/0008382
    Grant ostatní: Ministerstvo školství, mládeže a tělovýchovy - GA MŠk(CZ) CZ.02.1.01/0.0/0.0/16_026/0008382
    Institucionální podpora: RVO:61388955 ; RVO:68081707
    Klíčová slova: low-energy electrons * dissociative electron attachment * pyrimidine * radiosensitizer
    Obor OECD: Physical chemistry; Biochemistry and molecular biology (BFU-R)
    Impakt faktor: 5.924, rok: 2020
    Způsob publikování: Open access

    We report experimental results of low-energy electron interactions with 5-nitro-2,4-dichloropyrimidine isolated in the gas phase and hydrated in a cluster environment. The molecule exhibits a very rare combination of many so far hypothesized low-energy electron induced mechanisms, which may be responsible for synergism in concurrent chemo-radiation therapy of cancer. In contrast to many previous efforts to design an ideal radiosensitizer based on one mode of action, the present model molecule presents an alternative approach, where several modes of action are combined. With respect to the processes induced by the low-energy electrons, this is not a trivial task because of strong bond specificity of the dissociative electron attachment reaction, as it is discussed in the present paper. Unfortunately, low solubility and high toxicity of the molecule, as obtained from preliminary MTT assay tests, do not enable further studies of its activity in real biological systems but it can advantageously serve as a model or a base for rational design of radiosensitizers.
    Trvalý link: http://hdl.handle.net/11104/0312091

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0533836.pdf22.2 MBopen accessVydavatelský postprintpovolen
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.