Počet záznamů: 1  

Continuous rheological description of highly filled polymer melts for material extrusion

  1. 1.
    0525360 - ÚH 2021 RIV NL eng J - Článek v odborném periodiku
    Filip, Petr - Hausnerová, B. - Hnátková, E.
    Continuous rheological description of highly filled polymer melts for material extrusion.
    Applied Materials Today. Roč. 20, September (2020), č. článku 100754. ISSN 2352-9407. E-ISSN 2352-9407
    Grant CEP: GA ČR GA17-26808S
    Institucionální podpora: RVO:67985874
    Klíčová slova: material extrusion * highly filled melts * flow performance * true viscosity * master curve
    Obor OECD: Fluids and plasma physics (including surface physics)
    Impakt faktor: 10.041, rok: 2020
    Způsob publikování: Open access
    https://www.sciencedirect.com/science/article/pii/S2352940720302006?via%3Dihub

    In additive manufacturing based on the material extrusion of filled polymer melts, a correct description of the rheological behaviour of the processed material is an important requirement. In case of highly filled feedstocks, complexities connected with a proper flow description are not only caused by the high pack- aging of powder particles (more than 50 vol.%) but also by the notable participation of polymer binder components in the quantification of shear viscosity. In this study, analytical expressions (master curves) of a true shear viscosity are developed to follow and continuously optimize the rheological dependence of the bulk feedstock on particular variables. A nickel-chromium-based compound (Inconel 718, content 59 vol.%) with thermoplastic binders of different molecular weight of polyethylene glycol was selected for the case study. The proposed master curves comprise simultaneously hitherto separately applied two corrections of an apparent shear viscosity: regarding the different capillary geometries with respect to en- trance pressure and outlet extension, and determining an actual velocity profile based on shear rate dis- tribution inside a feedstock. This approach eliminates the hitherto used non-Newtonian index, by means of which the logarithmic derivative was approximated. As the master curves depend exclusively on the shear rate and molecular weight of polyethylene glycol and do not involve any adjustable parameter, their application is straightforward. Their accuracy does not exceed experimental errors.
    Trvalý link: http://hdl.handle.net/11104/0309604

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.