In-situ X-ray differential micro-tomography for investigation of water-weakening in quasi-brittle materials subjected to four-point bending

  1. 1.
    0523139 - ÚTAM 2021 RIV CH eng J - Článek v odborném periodiku
    Koudelka_ml., Petr - Fíla, Tomáš - Rada, Václav - Zlámal, Petr - Šleichrt, Jan - Vopálenský, Michal - Kumpová, Ivana - Beneš, Pavel - Vavřík, Daniel - Vavro, Leona - Vavro, Martin - Drdácký, Miloš - Kytýř, Daniel
    In-situ X-ray differential micro-tomography for investigation of water-weakening in quasi-brittle materials subjected to four-point bending.
    Materials. Roč. 13, č. 6 (2020), č. článku 1405. E-ISSN 1996-1944
    Grant CEP: GA MŠMT(CZ) EF16_019/0000766
    Institucionální podpora: RVO:68378297 ; RVO:68145535
    Klíčová slova: fracture propagation * in-situ X-ray 4D micro-CT * differential tomography * digital volume correlation * quasi-brittle materials * water-weakening * four-point bending
    Obor OECD: Materials engineering; Environmental and geological engineering, geotechnics (UGN-S)
    Impakt faktor: 3.623, rok: 2020
    Způsob publikování: Open access
    https://doi.org/10.3390/ma13061405

    Several methods, including X-ray radiography, have been developed for the investigation of the characteristics of water-saturated quasi-brittle materials. Here, the water content is one of the most important factors influencing their strength and fracture properties, in particular, as regards to porous building materials. However, the research concentrated on the three-dimensional fracture propagation characteristics is still significantly limited due to the problems encountered with the instrumentation requirements and the size e_ect. In this paper, we study the influence of the water content in a natural quasi-brittle material on its mechanical characteristics and fracture development during in-situ four-point bending by employing high-resolution X-ray di_erential micro-tomography. The cylindrical samples with a chevron notch were loaded using an in-house designed four-point bending loading device with the vertical orientation of the sample. The in-house designed modular micro-CT scanner was used for the visualisation of the specimen’s behaviour during the loading experiments. Several tomographic scans were performed throughout the force-displacement diagrams of the samples. The reconstructed 3D images were processed using an in-house developed di_erential tomography and digital volume correlation algorithms. The apparent reduction in the ultimate strength was observed due to the moisture content. The crack growth process in the water-saturated specimens was identified to be di_erent in comparison with the dry specimens
    Trvalý link: http://hdl.handle.net/11104/0307537

     
     