Počet záznamů: 1  

Wall-jet ion sensor based on ion transfer processes at a polarized room-temperature ionic liquid membrane

  1. 1.
    0523056 - ÚFCH JH 2021 RIV CH eng J - Článek v odborném periodiku
    Langmaier, Jan - Josypčuk, Bohdan - Samec, Zdeněk
    Wall-jet ion sensor based on ion transfer processes at a polarized room-temperature ionic liquid membrane.
    Journal of Electroanalytical Chemistry. Roč. 861, MAR 2020 (2020), č. článku 113948. ISSN 1572-6657. E-ISSN 1873-2569
    Grant CEP: GA ČR(CZ) GA20-07350S
    Institucionální podpora: RVO:61388955
    Klíčová slova: Electrochemical detection * Ion transfer voltammetry * Liquid-liquid interface * Room temperature ionic liquid * Wall-jet sensor
    Obor OECD: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
    Impakt faktor: 4.464, rok: 2020
    Způsob publikování: Omezený přístup

    Room-temperature ionic liquid (RTIL) membrane is used to construct a wall-jet ion sensor based on the ion transfer processes at a polarized interface between RTIL and an aqueous electrolyte solution. The stream of the aqueous phase with an injected sample plug containing an electroactive ion is led against the RTIL membrane through a silver tube, which is covered with an AgCl layer, and which serves simultaneously as one of two reference electrodes in a four-electrode cell. The effects of the applied potential, the ion concentration, the volume flow rate of the mobile aqueous phase, and the injected sample volume on the chronoamperometric response of the sensor to the test samples containing tetraethylammonium cation (TEA+) as a model ion are demonstrated. The applicability of the available theory of the wall-jet electrode against which a vertical stream is flowing that is much smaller in diameter than the electrode is confirmed for this sensor. Analytical characteristics for the flow injection analysis of the studied model ion are estimated including excellent repeatability characterized by the relative standard deviation (1.64%) of the average current at the ion concentration (0.5 μmol dm−3), a low limit of detection (22.5 nmol dm−3), and the wide linear dynamic range exceeding three orders of magnitude (1 × 10−7–2 × 10−4 mol dm−3).
    Trvalý link: http://hdl.handle.net/11104/0307463

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0523056.pdf11.1 MBVydavatelský postprintvyžádat
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.