Počet záznamů: 1  

Charge collection and field profile studies of heavily irradiated strip sensors for the ATLAS inner tracker upgrade

  1. 1.
    0522534 - FZÚ 2020 RIV NL eng J - Článek v odborném periodiku
    Hara, K. - Allport, P.P. - Baca, M. - Broughton, J. - Chisholm, A. - Nikolopoulos, K. - Pyatt, S. - Thomas, J. P. - Wilson Jr., L. - Kierstead, J. - Kuczewski, P. - Lynn, D. - Arratia, M. - Hommels, L. B. A. - Ullan, M. - Bloch, I. - Gregor, I. M. - Tackmann, K. - Trofimov, A. - Yildirim, E. - Hauser, M. - Jakobs, K. - Kuehn, S. - Mahboubi, K. - Mori, R. - Parzefall, U. - Clark, A. - Ferrere, D. - Ashby, J. - Blue, A. - Bates, R. - Buttar, C. - Doherty, F. - McMullen, T. - McEwan, F. - O'Shea, V. - Kamada, S. - Yamamura, K. - Ikegami, Y. - Nakamura, K. - Takubo, Y. - Unno, Y. - Takashima, R. - Chilingarov, A. - Fox, H. - Affolder, A. A. - Casse, G. - Dervan, P. - Forshaw, D. - Greenall, A. - Wonsak, S. - Wormald, M. - Cindro, V. - Kramberger, G. - Mandic, I. - Mikuz, M. - Gorelov, I. - Hoeferkamp, M. - Palni, P. - Seidel, S. - Taylor, A. - Toms, K. - Wang, R. - Hessey, N. P. - Valencic, N. - Hanagaki, K. - Doležal, Z. - Kodys, P. - Böhm, Jan - Mikeštíková, Marcela - Bevan, A. - Beck, G. - Milke, C. - Domingo, M. - Fadeyev, V. - Galloway, Z. - Hibbard-Lubow, D. - Liang, Z. - Sadrozinski, H. F.W. - Seiden, A. - To, K. - French, R. - Hodgson, P. - Marin-Reyes, H. - Parker, K. - Jinnouchi, O. - Sato, K. - Hagihara, M. - Iwabuchi, S. - Bernabeu, J. - Civera, J. V. - Garcia, C. - Lacasta, C. - Marti i Garcia, S. - Rodriguez, D. - Santoyo, D. - Solaz, C. - Soldevila, U. … celkem 101 autorů
    Charge collection and field profile studies of heavily irradiated strip sensors for the ATLAS inner tracker upgrade.
    Nuclear Instruments & Methods in Physics Research Section A. Roč. 831, Sep (2016), s. 181-188. ISSN 0168-9002. E-ISSN 1872-9576
    Grant CEP: GA MŠMT(CZ) LG13009
    GRANT EU: European Commission(XE) 654168 - AIDA-2020
    Institucionální podpora: RVO:68378271
    Klíčová slova: high luminosity large Hadron collider * micro strip sensor * charge collection * edge transient current technique * field profile
    Obor OECD: Particles and field physics
    Impakt faktor: 1.362, rok: 2016
    Způsob publikování: Omezený přístup
    https://doi.org/10.1016/j.nima.2016.04.035

    The ATLAS group has evaluated the charge collection in silicon microstrip sensors irradiated up to a fluence of 1×1016 n eq /cm 2 , exceeding the maximum of 1.6×1015 n eq /cm 2 expected for the strip tracker during the high luminosity LHC (HL-LHC) period including a safety factor of 2. The ATLAS12, n + -on-p type sensor, which is fabricated by Hamamatsu Photonics (HPK) on float zone (FZ) substrates, is the latest barrel sensor prototype. The charge collection from the irradiated 1×1 cm 2 barrel test sensors has been evaluated systematically using penetrating β-rays and an Alibava readout system. The data obtained at different measurement sites are compared with each other and with the results obtained from the previous ATLAS07 design. The results are very consistent, in particular, when the deposit charge is normalized by the sensor's active thickness derived from the edge transient current technique (edge-TCT) measurements.

    Trvalý link: http://hdl.handle.net/11104/0307013

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.