Počet záznamů: 1  

Effect of testing method type and specimen size on mode I fracture toughness of Kimachi sandstone

  1. 1.
    0509117 - ÚGN 2020 RIV JP eng J - Článek v odborném periodiku
    Kataoka, M. - Obara, Y. - Vavro, Leona - Souček, Kamil - Cho, S. H. - Jeong, S-S.
    Effect of testing method type and specimen size on mode I fracture toughness of Kimachi sandstone.
    Journal of the Mining and Materials Processing Institute of Japan. Roč. 135, č. 5 (2019), s. 33-41. ISSN 1881-6118. E-ISSN 1884-0450
    Institucionální podpora: RVO:68145535
    Klíčová slova: mode I fracture toughness * testing method type * specimen size * Kimachi sandstone
    Obor OECD: Environmental and geological engineering, geotechnics
    Způsob publikování: Open access
    https://www.jstage.jst.go.jp/article/journalofmmij/135/5/135_33/_article/-char/en

    Several testing methods have been proposed for evaluating the mode I fracture toughness of rocks. Since the fracture toughness evaluated from the different testing methods is generally not compared, what is still not wellknown is the effect of the testing method type on the fracture toughness. The effect of not only the testing method type but also the specimen size exists in the fracture toughness of rock materials. To clarify the effect of the testing method type and specimen size on the fracture toughness, many fracture toughness tests were performed in the
    previous experimental studies. However, the effect has not been elucidated because the number of the specimens is limited and the range of the specimen size is relatively small in the previous works. In this paper, firstly, three types of the fracture toughness test, the chevron bend (CB) test, semi-circular bend (SCB) test and straight notched disk bending (SNDB) test, were performed using Kimachi sandstone. Then, the SCB test was carried out using the same sandstone with various specimen sizes. As a result, the fracture toughness obtained from the CB and SCB tests were compatible each other. However, the SNDB tests estimated lower value of the fracture toughness than the others. From the results of the SCB tests with various specimen sizes, the fracture toughness increased with increasing radius. Based on the results, the effect of the specimen size on the fracture toughness and the differences
    of the fracture toughness obtained from the three testing methods were discussed.
    Trvalý link: http://hdl.handle.net/11104/0299905

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    UGN_0509117.pdf46.6 MBVydavatelský postprintpovolen
     
Počet záznamů: 1  