Počet záznamů: 1  

Investigation of droplet nucleation in CCS relevant systems: Progress in the design and testing of the mixture preparation device

  1. 1.
    0506392 - ÚT 2023 RIV FR eng C - Konferenční příspěvek (zahraniční konf.)
    Vinš, Václav - Čenský, Miroslav - Hrubý, Jan - Hykl, Jiří
    Investigation of droplet nucleation in CCS relevant systems: Progress in the design and testing of the mixture preparation device.
    EPJ Web of Conferences. Vol. 213. Les Ulis Cedex: EDP Sciences, 2019, č. článku 02092. E-ISSN 2100-014X.
    [EFM18 - Experimental Fluid Mechanics 2018. Prague (CZ), 13.11.2018-16.11.2018]
    Grant CEP: GA MŠMT(CZ) EF16_019/0000753
    Institucionální podpora: RVO:61388998
    Klíčová slova: carbon capture and storage * mixture preparation * capillary tube
    Obor OECD: Thermodynamics
    https://www.epj-conferences.org/articles/epjconf/abs/2019/18/epjconf_efm18_02092/epjconf_efm18_02092.html

    The study presents progress in the development of mixture preparation device (MPD) representing an important part of the larger experimental setup intended for investigation of homogeneous droplet nucleation in CO2-rich systems. MPD allows for accurate adjustment of flow parameters, i.e. temperature, pressure, and flow rate of CO2 in either superheated vapor or supercritical fluid phases and of other gas components such as argon or nitrogen. Through accurate settings of flow rates of individual components, the mixture composition can continuously be defined. MPD is going to be connected to the expansion chamber, where the droplet nucleation will experimentally be observed. In this work, CO2-branch, i.e. the core part of MPD, was modified and tested. Several components, e.g., pressure transducers and safety valve, had to be calibrated and adjusted to assure well-defined and safe operation. Most attention was paid to the design and performance of throttling capillary tubes installed in thermostatic bath, which define final flow parameters of CO2 coming from the CO2 branch. The flow characteristics of two capillary tubes with lengths of 7.8 and 4.0 m and inner diameter 0.1 mm were measured and compared to the predictions of a numerical model. The 1-D model of isothermal capillary flow was found to provide quite good agreement with the measured data.
    Trvalý link: http://hdl.handle.net/11104/0298327

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.