Počet záznamů: 1  

Simple Approaches to on-Line and off-Line Speciation Analysis of Mercury in Flue Gases with Detection by Atomic Absorption Spectrometry: A Pilot Study.

  1. 1.
    0504870 - ÚCHP 2020 RIV NL eng J - Článek v odborném periodiku
    Švehla, Jaroslav - Žídek, R. - Ružovič, Tomáš - Svoboda, Karel - Kratzer, J.
    Simple Approaches to on-Line and off-Line Speciation Analysis of Mercury in Flue Gases with Detection by Atomic Absorption Spectrometry: A Pilot Study.
    Spectrochimica Acta Part B: Atomic Spectroscopy. Roč. 156, JUN (2019), s. 51-58. ISSN 0584-8547. E-ISSN 1873-3565
    Grant CEP: GA MŠMT(CZ) EF16_026/0008413
    Institucionální podpora: RVO:67985858
    Klíčová slova: mercury * speciation analysis * flue gases
    Obor OECD: Environmental sciences (social aspects to be 5.7)
    Impakt faktor: 3.086, rok: 2019
    Způsob publikování: Omezený přístup

    Two simple approaches to speciation analysis of mercury in flue gases have been developed distinguishing between elemental mercury Hg 0 and oxidized form of mercury (often HgCl 2 )either in off-line or on-line measurement arrangements. Both approaches employ atomic absorption spectrometry (AAS)as a detector. The off-line approach combines a pair of sorbents from which the first one traps oxidized for of mercury (HgCl 2 )selectively on a raw alumina sorbent while the second one retains Hg 0 quantitatively on a gold-coated alumina filling. Trapped amount of Hg in both sorbents is subsequently determined by AAS employing the advanced mercury analyzer AMA-254. Both sorbents can be regenerated for repeated use. Selectivity and capacity of both sorbents was investigated by means of model gases and compared to other materials. The accuracy and precision of this approach have been proven by analysis of a model flue gas mixture. The on-line approach to speciation analysis is based on direct introduction of flue gases into the AAS spectrometer equipped with an externally heated quartz tube atomizer. The temperature of the atomizer's optical arm or temperature of the gas line upstream the atomizer allow speciation analysis since Hg 0 as atomic Hg-vapor can be detected at ambient temperature while HgCl 2 as a molecular species requires heating of the atomizer or gas line to 900 °C.
    Trvalý link: http://hdl.handle.net/11104/0296414

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0504870.pdf9976.7 KBAutorský postprintvyžádat
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.