Počet záznamů: 1  

Design of a zero‐gap laboratory‐scale polymer electrolyte membrane alkaline water electrolysis stack

  1. 1.
    0504836 - ÚMCH 2020 RIV DE eng J - Článek v odborném periodiku
    Hnát, J. - Kodým, R. - Denk, K. - Paidar, M. - Žitka, Jan - Bouzek, K.
    Design of a zero‐gap laboratory‐scale polymer electrolyte membrane alkaline water electrolysis stack.
    Chemie Ingenieur Technik. Roč. 91, č. 6 (2019), s. 821-832. ISSN 0009-286X. E-ISSN 1522-2640
    Institucionální podpora: RVO:61389013
    Klíčová slova: alkaline water electrolysis * gas separation * mathematical modeling
    Obor OECD: Polymer science
    Impakt faktor: 1.147, rok: 2019
    Způsob publikování: Omezený přístup
    https://onlinelibrary.wiley.com/doi/full/10.1002/cite.201800185

    he development of a zero‐gap alkaline water electrolysis stack based on a heterogeneous anion‐selective polymer electrolyte membrane is reported. A bipolar electrode arrangement was selected as the most appropriate one. The design was targeted to verify the suitability of the membrane electrode assembly design and the functionality of the gas separator system developed together with the purity of the gases produced. The influence of various operational regimes on the purity of the gases was investigated. Last, but not least, a validation of the mathematical model to be used for scale‐up of the cell, foreseen for the next step of the project, was performed.