Počet záznamů: 1  

Damage accumulation and implanted Gd and Au position in a- and c-plane GaN

  1. 1.
    0504789 - ÚJF 2020 RIV CH eng J - Článek v odborném periodiku
    Macková, Anna - Malinský, Petr - Jagerová, Adéla - Mikšová, Romana - Sofer, Z. - Klímová, K. - Mikulics, M. - Bottger, R. - Akhmadaliev, S. - Oswald, Jiří
    Damage accumulation and implanted Gd and Au position in a- and c-plane GaN.
    Thin Solid Films. Roč. 680, č. 6 (2019), s. 102-113. ISSN 0040-6090. E-ISSN 1879-2731
    Grant CEP: GA MŠMT EF16_013/0001812; GA MŠMT LM2015056; GA ČR GA18-03346S
    Institucionální podpora: RVO:68378271 ; RVO:61389005
    Klíčová slova: Implanted (0001) and (11-20) GaN * Damage accumulation asymmetry in GaN * Ion implantation in semiconductors * RBS channelling * Damage-depth profiling
    Obor OECD: Nuclear physics; Condensed matter physics (including formerly solid state physics, supercond.) (FZU-D)
    Impakt faktor: 2.030, rok: 2019
    Způsob publikování: Omezený přístup
    https://doi.org/10.1016/j.tsf.2019.04.035

    Abstract: (0001) c-plane and (11-20) a-plane GaN epitaxial layers were implanted with 400 keV Au+ and Gd+ ions using ion implantation fluences of 5x10(14), 1x10(15) and 5x10(15) cm(-2). Rutherford Back-Scattering spectrometry in channelling mode (RBS/C) was used to follow the dopant depth profiles and the introduced disorder, the angular dependence of the backscattered ions (angular scans) in c-and a-plane GaN was measured to get insight into structural modification and dopant position in various crystallographic orientations. Defect-accumulation depth profiles exhibited differences for a-and c-plane GaN, with a-plane showing significantly lower accumulated disorder in the buried layer, accompanied by the shift of the maximum damage accumulation into the deeper layer with respect to the theoretical prediction, than c-plane GaN. Angular scans showed channelling preservation in as-implanted samples and better channelling recovery in the annealed a-plane GaN compared to c-plane GaN. The angular scan widths were simulated by FLUX code as well as the half-width modifications of angular scans were discussed in connection to the damage accumulation. Photoluminescence measurement followed in detail yellow band and band edge luminescence decline after the implantation and the recovery of luminescence spectra features after annealing.
    Trvalý link: http://hdl.handle.net/11104/0296342

     
     