Effect of Particle Image Velocimetry setting parameters on local velocity measurements in an agitated vessel

  1. 1.
    0501006 - ÚH 2020 RIV DE eng J - Článek v odborném periodiku
    Šulc, R. - Ditl, P. - Jašíková, D. - Kotek, M. - Kopecký, V. - Kysela, Bohuš
    Effect of Particle Image Velocimetry setting parameters on local velocity measurements in an agitated vessel.
    Chemical Engineering & Technology. Roč. 42, č. 4 (2019), s. 827-834. ISSN 0930-7516. E-ISSN 1521-4125
    Grant CEP: GA ČR GA16-20175S
    Grant ostatní: GA MŠk(CZ) LO1201
    Institucionální podpora: RVO:67985874
    Klíčová slova: mixing * Rushton turbine * Particle Image Velocimetry * fluctuation velocity * fluctuation velocity gradient
    Obor OECD: Fluids and plasma physics (including surface physics)
    Impakt faktor: 1.543, rok: 2019
    Způsob publikování: Open access

    Although they are obtained under the same conditions, results on the flow field in an agitated vessel achieved using particle image velocimetry (PIV) may vary due to differences in the PIV conditions. The influence on turbulence characteristics of the main PIV setting parameters, i.e., PIV spatial resolution, sampling frequency, and recording time, was investigated. Tests were performed with three different liquids in a developed turbulent field for a Rushton turbine impeller using two-dimensional time-resolved PIV. To obtain the relevant velocity gradients, a minimum recording time is needed. No effect of sampling frequency was observed if the sampling frequency was higher than approximately 17 times the impeller frequency, which is about three times the impeller blade frequency.
    Trvalý link: http://hdl.handle.net/11104/0295656

     