Počet záznamů: 1  

Optical microchips based on high-affinity recombinant protein binders-Human serum albumin detection in urine

  1. 1.
    0495868 - BTÚ 2019 RIV CH eng J - Článek v odborném periodiku
    Semeradtová, A. - Stofik, M. - Vaňková, Lucie - Malý, Petr - Staněk, Ondřej - Malý, J.
    Optical microchips based on high-affinity recombinant protein binders-Human serum albumin detection in urine.
    Sensors and Actuators B - Chemical. Roč. 272, NOV 1 2018 (2018), s. 441-447. E-ISSN 0925-4005
    Grant CEP: GA MŠMT(CZ) ED1.1.00/02.0109; GA MZd(CZ) NV16-29738A; GA MŠMT(CZ) EF16_013/0001818
    Grant ostatní: GA MŠk(CZ) CZ.02.1.01/0.0/0.0/16_013/0001821
    Institucionální podpora: RVO:86652036 ; RVO:61388971
    Klíčová slova: Microarrays * Biosensors * Protein binders
    Obor OECD: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis); Analytical chemistry (MBU-M)
    Impakt faktor: 6.393, rok: 2018

    Recent developments in molecular evolution technologies have led to novel types of high-affinity recombinant protein binders (PB) able to substitute antibodies in many diagnostic and therapeutic applications. Despite almost a decade of research, they have so far only been sporadically used for biosensor construction. Here, we present a proof-of-principle comparative study focused on the application of three types of PB recognizing human serum albumin (HSA) in the fabrication of diagnostic optical microchips detecting clinically relevant HSA levels in urine. The PB tested were: (i) biotinylated anti-HSA Affibody (AF) (IgG binding domain of protein A, Staphylococcus aureus), (ii) biotinylated protein construct based on albumin-binding domain (ABD) of protein G (Streptococcus G148) fused with long TolA spacer (6xHis-WT-ABD-TolA-AviTag) and (iii) WT-ABD-Trp leaderstreptavidin tetrameric fusion protein (SA-ABD-WT). Open glass microchips with 24 independent microwells (volume 8 mu L) and micropatterned detection zones were prepared and used for oriented binding of proteins through the biotin/streptavidin chemistry. The analytical performance of the optical microchips was tested by performing direct specific detection of fluorescently labelled HSA in various environments. Results show that the length of peptide spacer present between the binding protein domain and sensor surface is a key factor influencing biosensor performance. The biosensor based on SA-ABD-WT reached the limit of detection (LOD) for HSA in urine (LOD=0.65 mu g/ml) sufficient to identify the chronic kidney disease caused by high blood pressure or diabetes. Furthermore, it offers the highest signal intensity, low noise and significant simplification of microchip preparation due to a simple one-step immobilization procedure. Our results may be further exploited in development of diagnostic microchips dedicated to the detection of a wide range of molecular targets recognized by specific ABD protein binders.
    Trvalý link: http://hdl.handle.net/11104/0288754

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    Semeradtova_et_al_2018.pdf11.2 MBAutorský preprintvyžádat
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.