Počet záznamů: 1  

Effective water cooling of very hot surfaces during the LOCA accident.

  1. 1.
    0481374 - ÚFP 2018 RIV CH eng J - Článek v odborném periodiku
    Štepánek, J. - Bláha, V. - Dostál, V. - Entler, Slavomír
    Effective water cooling of very hot surfaces during the LOCA accident.
    Fusion Engineering and Design. Roč. 124, November (2017), s. 1211-1214. ISSN 0920-3796. E-ISSN 1873-7196.
    [SOFT 2016: Symposium on Fusion Technology /29./. Prague, 05.09.2016-09.09.2016]
    Institucionální podpora: RVO:61389021
    Klíčová slova: LOCA * Quenching * Divertor cooling * Heat transfer * Rewetting
    Obor OECD: Nuclear related engineering
    Impakt faktor: 1.437, rok: 2017
    http://www.sciencedirect.com/science/article/pii/S0920379617303733

    The quench front propagation in the case of the water emergency cooling of water cooled fusion nuclear components is studied during the LOCA accident. In the case of the LOCA accident, heat removal can be successful only when water rewetts the surface. The place where water meets the very hot surface is called the quench front. The quench front propagation depends on the initial wall temperature, coolant flow rate, and heat accumulated in the cooled components. Results of the quench front experiment in an annular 1.7 m length channel with initial wall temperatures within the range from 250 degrees C up to 800 degrees C and coolant mass fluxes 100 kg/m(2) s and 180 kg/m(2) s are presented. From the results is concluded, that quenching velocities and rewetting temperatures are strongly dependent on the initial wall temperature as well as the pressure spikes. The behaviour of the heat transfer coefficient at the quench front is analyzed.

    Trvalý link: http://hdl.handle.net/11104/0276955

     
     
Počet záznamů: 1  