Počet záznamů: 1  

Compositional, structural, and optical changes of polyimide implanted by 1.0 MeV Ni+ ions

  1. 1.
    0479626 - ÚJF 2018 RIV NL eng J - Článek v odborném periodiku
    Mikšová, Romana - Macková, Anna - Pupíková, Hana - Malinský, Petr - Slepička, P. - Švorčík, V.
    Compositional, structural, and optical changes of polyimide implanted by 1.0 MeV Ni+ ions.
    Nuclear Instruments & Methods in Physics Research Section B. Roč. 406, SEP (2017), s. 199-204. ISSN 0168-583X. E-ISSN 1872-9584
    Grant CEP: GA MŠMT LM2015056; GA ČR(CZ) GBP108/12/G108
    Institucionální podpora: RVO:61389005
    Klíčová slova: Ni ion implantation * polyimide * polymer degradation
    Obor OECD: Nuclear physics
    Impakt faktor: 1.323, rok: 2017

    he ion irradiation leads to deep structural and compositional changes in the irradiated polymers. Ni+ ions implanted polymers were investigated from the structural and compositional changes point of view and their optical properties were investigated. Polyimide (PI) foils were implanted with 1.0 MeV Ni+ ions at room temperature with fluencies of 1.0 x 10(13)-1.0 x 10(15) cm(-2) and two different ion implantation currents densities (3.5 and 7.2 nA/cm(2)). Rutherford Back-Scattering (RBS) and Elastic Recoil Detection Analysis (ERDA) were used for determination of oxygen and hydrogen escape in implanted PI. Atomic Force Microscopy (AFM) was used to follow surface roughness modification after the ion implantation and UV-Vis spectroscopy was employed to check the optical properties of the implanted PI. The implanted PI structural changes were analysed using Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR).
    High energy Ni-ion implantation causes only a minor release of hydrogen and oxygen close to the polymer sub-surface region in about 60 nm thick layer penetrated by the ion beam, especially at ion fluencies below 1.0 x 10(14) cm(-2). The mostly pronounced structural changes of the Ni implanted PI were found for the samples implanted above ion fluence 1.0 x 10(15) cm(-2) and at the ion current density 7.2 nA/cm(2), where the optical band gap significantly decreases and the reduction of more complex structural unit of PI monomer was observed.
    Trvalý link: http://hdl.handle.net/11104/0275602

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.