Počet záznamů: 1  

Polarization Calibration of the Chromospheric Lyman-Alpha SpectroPolarimeter for a 0.1% Polarization Sensitivity in the VUV Range. Part II: In-Flight Calibration

  1. 1.
    0478693 - ASÚ 2018 NL eng J - Článek v odborném periodiku
    Giono, G. - Ishikawa, R. - Narukage, N. - Kano, R. - Katsukawa, Y. - Kubo, M. - Ishikawa, S. - Bando, T. - Hara, H. - Suematsu, Y. - Winebarger, A. - Kobayashi, K. - Auchere, F. - Trujillo Bueno, J. - Tsuneta, S. - Shimizu, T. - Sakao, T. - Cirtain, J. - Champey, P. - Asensio Ramos, A. - Štěpán, Jiří - Belluzzi, L. - Sainz, R.M. - de Pontieu, B. - Ichimoto, K. - Carlsson, M. - Casini, R. - Goto, M.
    Polarization Calibration of the Chromospheric Lyman-Alpha SpectroPolarimeter for a 0.1% Polarization Sensitivity in the VUV Range. Part II: In-Flight Calibration.
    Solar Physics. Roč. 292, č. 4 (2017), 57/1-57/19. ISSN 0038-0938. E-ISSN 1573-093X
    Grant CEP: GA ČR(CZ) GA16-16861S
    Institucionální podpora: RVO:67985815
    Klíčová slova: solar transition region * ly-alpha * magnetohydrodynamic model
    Obor OECD: Astronomy (including astrophysics,space science)
    Impakt faktor: 2.580, rok: 2017

    The Chromospheric Lyman-Alpha SpectroPolarimeter is a sounding rocket instrument designed to measure for the first time the linear polarization of the hydrogen Lyman-alpha line (121.6 nm). The instrument was successfully launched on 3 September 2015 and observations were conducted at the solar disc center and close to the limb during the five minutes flight. In this article, the disc center observations are used to provide an in-flight calibration of the instrument spurious polarization. The derived in-flight spurious polarization is consistent with the spurious polarization levels determined during the pre-flight calibration and a statistical analysis of the polarization fluctuations from solar origin is conducted to ensure a 0.014% precision on the spurious polarization. The combination of the pre-flight and the in-flight polarization calibrations provides a complete picture of the instrument response matrix, and a proper error transfer method is used to confirm the achieved polarization accuracy. As a result, the unprecedented 0.1% polarization accuracy of the instrument in the vacuum ultraviolet is ensured by the polarization calibration.
    Trvalý link: http://hdl.handle.net/11104/0274753

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.