Počet záznamů: 1  

Number Concentrations and Modal Structure of Indoor/Outdoor Fine Particles in Four European Cities.

  1. 1.
    0469251 - ÚCHP 2017 RIV TW eng J - Článek v odborném periodiku
    Lazaridis, M. - Eleftheriadis, K. - Ždímal, Vladimír - Schwarz, Jaroslav - Wagner, Zdeněk - Ondráček, Jakub - Drossinos, Y. - Glytsos, T. - Vratolis, S. - Torseth, K. - Moravec, Pavel - Hussein, T. - Smolík, Jiří
    Number Concentrations and Modal Structure of Indoor/Outdoor Fine Particles in Four European Cities.
    Aerosol and Air Quality Research. Roč. 17, č. 1 (2017), s. 131-146. ISSN 1680-8584. E-ISSN 2071-1409
    GRANT EU: European Commission(XE) 315760 - HEXACOMM
    Institucionální podpora: RVO:67985858
    Klíčová slova: indoor/outdoor aerosol * I/O ratio * modal structure
    Obor OECD: Meteorology and atmospheric sciences
    Impakt faktor: 2.589, rok: 2017

    Indoor/outdoor aerosol size distribution was measured in four European cities (Oslo–Norway, Prague–Czech Republic, Milan–Italy and Athens–Greece) during 2002 in order to examine the differences in the characteristics of the indoor/outdoor modal structure and to evaluate the effect of indoor sources to the aerosol size distributions. All the measurement sites were naturally ventilated and were occupied during the campaigns by permanent residents or for certain time periods by the technical staff responsible for the instrumentation. Outdoor particle number (PN) concentrations presented the higher values in Milan and Athens (median values 1.4×104 #/cm3and 2.9×104 #/cm3 respectively) as a result of elevated outdoor emissions and led to correspondingly higher indoor values compared to Oslo and Prague. In absence of indoor activities, the indoor concentrations followed the fluctuations of the outdoor concentrations in all the measurement sites. Indoor activities (cooking, smoking, etc) resulted in elevated indoor PN concentrations (maximum values ranging between 1.7×105 #/cm3 and 3.2×105 #/cm3) and to I/O ratios higher than one. The I/O ratios were size dependant and for periods without indoor activities they presented the lowest values for particles <50 nm (0.51±0.15) and the ratios increased with fine particle size (0.79±0.12 for particles between 100-200 nm). The analysis of the modal structure showed that the indoor aerosol size distribution characteristics differ from the outdoors under the effect of indoor sources. The percentage of unimodal size distributions increased during indoor emissions, compared to periods without indoor sources, along with the number concentration of Aitken mode particles, indicating emissions in specific size ranges according to the type of the indoor source.
    Trvalý link: http://hdl.handle.net/11104/0268613

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.