Počet záznamů: 1  

Length measurement in absolute scale via low-dispersion optical cavity

  1. 1.
    0468528 - ÚPT 2017 RIV US eng C - Konferenční příspěvek (zahraniční konf.)
    Pravdová, Lenka - Lešundák, Adam - Šmíd, Radek - Hrabina, Jan - Řeřucha, Šimon - Číp, Ondřej
    Length measurement in absolute scale via low-dispersion optical cavity.
    20th Slovak-Czech-Polish Optical Conference on Wave and Quantum Aspects of Contemporary Optics (Proceedings of SPIE 10142). Bellingham: SPIE, 2016, s. 1-5, č. článku 101420T. ISSN 0277-786X.
    [Slovak-Czech-Polish Optical Conference on Wave and Quantum Aspects of Contemporary Optics /20./. Jasná (SK), 05.09.2016-09.09.2016]
    Grant CEP: GA ČR GB14-36681G; GA MŠMT(CZ) LO1212; GA MŠMT ED0017/01/01
    Institucionální podpora: RVO:68081731
    Klíčová slova: absolute length measurement * dispersion * optical frequency comb * length metrology * Fabry-Perot * resonator
    Kód oboru RIV: BH - Optika, masery a lasery
    http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=2595365

    We report on the length measuring instrument with the absolute scale that was based on the combination of an optical frequency comb and a passive optical cavity. The time spacing of short femtosecond pulses, generated by the optical frequency comb, is optically phase locked onto the cavity free spectral range with a derivative spectroscopy technique so that the value of the repetition frequency of the femtosecond laser is tied to and determines the measured displacement. The instantaneous value of the femtosecond pulse train frequency is counted by a frequency counter. This counted value corresponds to the length given by the spacing between the two mirrors of the passive cavity. The phase lock between the femtosecond pulsed beam and the passive cavity is possible due to the low-dispersion of the cavity mirrors, where the silver coating on the mirrors was used to provide the low dispersion for the broadband radiation of the comb. Every reflection on the output mirror feeds a portion of the beam back to the cavity so that the output beam is a result of multiple interfering components. The parameters of the output beam are given not only by the parameters of the mirrors but mainly by the absolute distance between the mirror surfaces. Thus, one cavity mirror can be considered as the reference starting point of the distance to be measured and the other mirror is the measuring probe surveying the unknown distance. The measuring mirror of the experimental setup of the low-dispersion cavity is mounted on a piezoelectric actuator which provides small changes in the cavity length we used to test the length measurement method. For the verification of the measurement accuracy a reference incremental interferometer was integrated into our system so that the displacement of the piezoelectric actuator could be obtained with both measuring methods simultaneously.
    Trvalý link: http://hdl.handle.net/11104/0266502

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.