Počet záznamů: 1  

All-diamond functional surface micro-electrode arrays for brain-slice neural analysis

  1. 1.
    0465775 - ÚFCH JH 2018 RIV DE eng J - Článek v odborném periodiku
    Vahidpour, F. - Curley, L. - Biró, I. - McDonald, M. - Croux, D. - Pobedinskas, P. - Haenen, K. - Giugliano, M. - Vlčková Živcová, Zuzana - Kavan, Ladislav - Nesládek, M.
    All-diamond functional surface micro-electrode arrays for brain-slice neural analysis.
    Physica Status Solidi A. Roč. 214, č. 2 (2017), č. článku 1532347. ISSN 1862-6300. E-ISSN 1862-6319
    Grant CEP: GA ČR GA13-31783S
    Institucionální podpora: RVO:61388955
    Klíčová slova: impedance spectroscopy * microelectrode arrays * surface termination
    Obor OECD: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
    Impakt faktor: 1.795, rok: 2017

    Diamond-based microelectrode arrays were fabricated by using nanocrystalline diamond as an insulating layer and conductive boron-doped in order to used them for analysis of brain cortical slices. MEA surface is solely composed of diamond, exposed to the cells. The impedance measurements showed negligible cross-talk between neighbouring diamond microelectrodes. Local field potentials related to neural signals were then successfully recorded from pharmacologically disinhibited rat cortical tissue slices, mechanically coupled on the surface of the MEA. The background signal level of the diamond MEAs was found to be lower than commercial Pt-based MEAs, under identical measurement conditions.
    Trvalý link: http://hdl.handle.net/11104/0264231

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0465775.pdf01.3 MBVydavatelský postprintvyžádat
     
Počet záznamů: 1  