Počet záznamů: 1  

Profile measurements of the electron temperature on the ASDEX Upgrade, COMPASS, and ISTTOK tokamak using Thomson scattering, triple, and ball-pen probes

  1. 1.
    0459970 - ÚFP 2017 RIV US eng J - Článek v odborném periodiku
    Adámek, Jiří - Müller, H.W. - Silva, C. - Schrittwieser, R. - Ionita, C. - Mehlmann, F. - Costea, S. - Horáček, Jan - Kurzan, B. - Bílková, Petra - Böhm, Petr - Aftanas, Milan - Vondráček, Petr - Stöckel, Jan - Pánek, Radomír - Fernandes, H. - Figueiredo, H.
    Profile measurements of the electron temperature on the ASDEX Upgrade, COMPASS, and ISTTOK tokamak using Thomson scattering, triple, and ball-pen probes.
    Review of Scientific Instruments. Roč. 87, č. 4 (2016), č. článku 043510. ISSN 0034-6748. E-ISSN 1089-7623
    Grant CEP: GA ČR(CZ) GA15-10723S; GA ČR(CZ) GAP205/12/2327; GA ČR(CZ) GA14-35260S; GA MŠMT(CZ) LM2011021
    Institucionální podpora: RVO:61389021
    Klíčová slova: ball-pen probe (BPP) * ASDEX Upgrade * Langmuir probe (LP) * ISTTOK (Instituto Superior Tecnico TOKamak) * COMPASS (COMPact ASSembly),
    Obor OECD: 2.11 Other engineering and technologies
    Impakt faktor: 1.515, rok: 2016
    http://scitation.aip.org/content/aip/journal/rsi/87/4/10.1063/1.4945797

    The ball-pen probe (BPP) technique is used successfully to make profile measurements of the electron temperature on the ASDEX Upgrade (Axially Symmetric Divertor Experiment), COMPASS (COMPact ASSembly), and ISTTOK (Instituto Superior Tecnico TOKamak) tokamak. The electron temperature is provided by a combination of the BPP potential (Phi(BPP)) and the floating potential (V-fl) of the Langmuir probe (LP), which is compared with the Thomson scattering diagnostic on ASDEX Upgrade and COMPASS. Excellent agreement between the two diagnostics is obtained for circular and diverted plasmas and different heating mechanisms (Ohmic, NBI, ECRH) in deuterium discharges with the same formula T-e = (Phi(BPP) - V-fl)/2.2. The comparative measurements of the electron temperature using BPP/LP and triple probe (TP) techniques on the ISTTOK tokamak show good agreement of averaged values only inside the separatrix. It was also found that the TP provides the electron temperature with significantly higher standard deviation than BPP/LP. However, the resulting values of both techniques are well in the phase with the maximum of cross-correlation function being 0.8.
    Trvalý link: http://hdl.handle.net/11104/0260118

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0459970 _Adamek_1.4945797.pdf54.6 MBVydavatelský postprintvyžádat
     
Počet záznamů: 1  