Počet záznamů: 1  

Determining ablation depth using CT imaging

  1. 1.
    0455047 - FZÚ 2016 RIV CZ eng A - Abstrakt
    Urzová, J. - Jelínek, Miroslav - Remsa, Jan - Vopálka, R.
    Determining ablation depth using CT imaging.
    Progressive Biomedical Materials and Technologies 2015. Kladno: CTU Faculty of Biomedical Engineering, 2015 - (Jelínek, M.). s. 17. ISBN 978-80-01-05809-1.
    [Progressive Biomedical Materials and Technologies 2015. 09.10.2015-10.10.2015, Kladno]
    Institucionální podpora: RVO:68378271
    Klíčová slova: ablation depth * CT imaging * excimer laser
    Kód oboru RIV: BM - Fyzika pevných látek a magnetismus

    During the laser-tissue interaction several types of interactions take place depending on the energy density and wavelength of the incoming radiation. From a biomedical point of view the most interesting ones are the photoablative interactions, which effectively remove tissue via decomposition without excessive heat damage to the remaining tissue. The decomposition occurs through direct breaking of molecular bonds followed by swift dissipation of decomposed particles into surrounding space. Photoablation occurs at energy densities of 107 – 109 W.cm-2 and pulse durations of 10 – 100 ns. For specific medical applications it’s necessary to know the ablation depth, i.e. the thickness of the layer removed with a single laser pulse. A new method to determine the ablation crater’s depth was developed using CT imaging; the results produced by this method were compared to results gained by other means and values available in literature.
    Trvalý link: http://hdl.handle.net/11104/0255700

     
     