New design of microwave interferometer for tokamak COMPASS

  1. 1.
    0453771 - ÚFP 2016 RIV US eng J - Článek v odborném periodiku
    Varavin, Mykyta - Zajac, Jaromír - Žáček, František - Nanobashvili, S.I. - Ermak, G. - Varavin, A. - Vasilev, A. - Stumbra, M. - Vetoshko, A. - Fateev, A. - Shevchenko, V.
    New design of microwave interferometer for tokamak COMPASS.
    Telecommunications and Radio Engineering. Roč. 73, č. 10 (2014), s. 935-942. ISSN 0040-2508
    Institucionální podpora: RVO:61389021
    Klíčová slova: Microwave interferometry * Plasma diagnostics * Tokamak
    Kód oboru RIV: BL - Fyzika plazmatu a výboje v plynech
    http://www.dl.begellhouse.com/journals/0632a9d54950b268,0f0577fd35766f78,6e6cc5d616079cba.html

    The article deals with an improvement of the accuracy of the phase measurements commonly used in the microwave diagnostics of the plasma density. The main attention is devoted to the development and calibration of new phase detectors (PD) for microwave interferometer operating on tokamak COMPASS in IPP Prague. A special attention is paid to the phase error measurement. Emphasis is put on a proper error measurement and on the methodology of the errors correction.
    Trvalý link: http://hdl.handle.net/11104/0254485

     
     