Počet záznamů: 1  

Resonance tube or lax vox?

  1. 1.
    0447599 - ÚT 2016 RIV IT eng A - Abstrakt
    Tyrmi, J. - Radolf, Vojtěch - Horáček, Jaromír - Laukkanen, A. M.
    Resonance tube or lax vox?
    Pan European Voice Conference : PEVOC 11 - Abstract Book. Firenze: Firenze University Press, 2015 - (Manfredi, C.). s. 195-195. ISBN 978-88-6655-794-4.
    [Pan European Voice Conference : PEVOC /11./. 31.08.2015-02.09.2015, Firenze]
    Grant CEP: GA ČR(CZ) GAP101/12/1306
    Institucionální podpora: RVO:61388998
    Klíčová slova: phonation into tube * voice therapy * flow resistance * contact quotient
    Kód oboru RIV: BI - Akustika a kmity

    Voice training and therapy utilize phonation into tubes, the outer end either in the air or immersed in water. This study compares (1) flow resistance of resonance tube and lax vox tube when submerged 2 cm and 10 cm in water, and (2) phonation into resonance tube and lax vox tube with the outer end immersed 2 cm and 10 cm in water in a bowl. Flow resistance was slightly lower with lax vox tube than with resonance tube, and slightly lower for smaller immersion angles. Flow resistance was higher for lower flow values corresponding to soft phonation. The only significant difference was that contact quotient was somewhat lower for softer phonation into lax vox tube immersed 2 cm in water. It seems that the differences in length, material and inner diameter of resonance tube and lax vox tube have rather little effect on phonation. Due to the small number of subjects (three males and three females) the results are preliminary.
    Trvalý link: http://hdl.handle.net/11104/0249667

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.