Počet záznamů: 1  

Validation of GEANT4 Monte Carlo models with a highly granular scintillator-steel hadron calorimeter

  1. 1.
    0436962 - FZÚ 2015 RIV GB eng J - Článek v odborném periodiku
    Adloff, C. - Blaha, J. - Blaising, J.J. - Cvach, Jaroslav - Gallus, Petr - Havránek, Miroslav - Janata, Milan - Kvasnička, Jiří - Lednický, Denis - Marčišovský, Michal - Polák, Ivo - Popule, Jiří - Tomášek, Lukáš - Tomášek, Michal - Růžička, Pavel - Šícho, Petr - Smolík, Jan - Vrba, Václav - Zálešák, Jaroslav … celkem 173 autorů
    Validation of GEANT4 Monte Carlo models with a highly granular scintillator-steel hadron calorimeter.
    Journal of Instrumentation. Roč. 8, Jul (2013), s. 1-33. ISSN 1748-0221. E-ISSN 1748-0221
    Institucionální podpora: RVO:68378271
    Klíčová slova: interaction of radiation with matter * calorimeter methods * detector modelling and simulations
    Kód oboru RIV: BF - Elementární částice a fyzika vys. energií
    Impakt faktor: 1.526, rok: 2013

    The paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via silicon photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8 GeV to 100 GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists is evaluated.
    Trvalý link: http://hdl.handle.net/11104/0240553

     
     