Počet záznamů: 1  

Non-classical signature of parametric fluorescence and its application in metrology

  1. 1.
    0436679 - FZÚ 2015 RIV SK eng J - Článek v odborném periodiku
    Hamar, Martin - Michálek, Václav - Pathak, A.
    Non-classical signature of parametric fluorescence and its application in metrology.
    Measurement Science Review. Roč. 14, č. 4 (2014), s. 227-236. ISSN 1335-8871. E-ISSN 1335-8871
    Grant CEP: GA ČR GAP205/12/0382
    Institucionální podpora: RVO:68378271
    Klíčová slova: parametric fluorescence * photon number squeezed light * quantum efficiency
    Kód oboru RIV: BH - Optika, masery a lasery
    Impakt faktor: 0.989, rok: 2014

    The article provides a short theoretical background of what the non-classical light means. We applied the criterion for the existence of non-classical effects derived by C. T. Lee on parametric fluorescence. The criterion was originally derived for the study of two light beams with one mode per beam. We checked if the criterion is still working for two multimode beams of parametric down-conversion through numerical simulations. The theoretical results were tested by measurement of photon number statistics of twin beams emitted by nonlinear BBO crystal pumped by intense femtoseconds UV pulse. We used ICCD camera as the detector of photons in both beams. It appears that the criterion can be used for the measurement of the quantum efficiencies of the ICCD cameras.
    Trvalý link: http://hdl.handle.net/11104/0240352

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.