Počet záznamů: 1  

Determination of trace concentrations of transmuted stable nuclides in TMD detectors using PGAA

  1. 1.
    0429044 - ÚJF 2015 RIV NL eng J - Článek v odborném periodiku
    Tomandl, Ivo - Viererbl, L. - Kudějová, P. - Lahodová, Z. - Klupák, V. - Fikrle, Marek
    Determination of trace concentrations of transmuted stable nuclides in TMD detectors using PGAA.
    Journal of Radioanalytical and Nuclear Chemistry. Roč. 300, č. 3 (2014), s. 1141-1149. ISSN 0236-5731. E-ISSN 1588-2780
    Grant CEP: GA TA ČR TA01010237
    Institucionální podpora: RVO:61389005
    Klíčová slova: reactor dosimetry * neutron fluence * transmutation detector * prompt gamma activation analysis
    Kód oboru RIV: BG - Jaderná, atomová a mol. fyzika, urychlovače
    Impakt faktor: 1.034, rok: 2014

    The capability of prompt gamma-ray activation analysis (PGAA) for neutron fluence dosimetry by means of transmutation detectors is reported. The metallic foils of Ni, Au, Cu and Nb and the small piece of Ge crystal, which were irradiated at the LVR-15 reactor at A similar to eA3/4 for several days, were selected for analysis by PGAA technique. Concentrations of transmuted stable nuclides in these foils were measured using the PGAA facility installed at the research reactor FRM II in Garching.
    Trvalý link: http://hdl.handle.net/11104/0234227

     
     