Počet záznamů: 1  

Comparison of computed and measured acoustic characteristics of an artificially lengthened vocal tract

  1. 1.
    0421795 - ÚT 2014 RIV IT eng C - Konferenční příspěvek (zahraniční konf.)
    Radolf, Vojtěch - Horáček, Jaromír - Laukkanen, A. M.
    Comparison of computed and measured acoustic characteristics of an artificially lengthened vocal tract.
    Models and Analysis of Vocal Emissions for Biomedical Applications - proceedings. Firenze: Firenze University, 2013 - (Manfredi, C.), s. 51-53. ISBN 978-88-6655-469-1.
    [Models and Analysis of Vocal Emissions for Biomedical Applications /8./. Firenze (IT), 16.12.2013-18.12.2013]
    Grant CEP: GA ČR GPP101/12/P579
    Institucionální podpora: RVO:61388998
    Klíčová slova: biomechanics of voice * phonation into tubes * formant frequency
    Kód oboru RIV: BI - Akustika a kmity

    The First formant frequency F1 of a human vocal tract (VT) prolonged with a glass tube was measured for a VT model with solid walls and a real human VT, and the results were compared to a mathematical model. The experiments with the VT model confirmed the legitimacy of an assumption of the solid walls in the mathematical simulations of acoustical characteristics of the artificial VT plexiglass model prolonged with the tube. The measured F1=73 Hz well corresponded to the computed value 78 Hz. However, the in vivo experiments in human, performed in a similar way, showed a much higher value of F1 at about 200 Hz, that is caused by soft tissues on the walls of real human VT cavities.