Počet záznamů: 1  

Two strategies of lowering surface deformations of internally cooled X-ray optics

  1. 1.
    0398841 - FZÚ 2014 RIV NL eng J - Článek v odborném periodiku
    Oberta, Peter - Áč, V. - Hrdý, Jaromír
    Two strategies of lowering surface deformations of internally cooled X-ray optics.
    Nuclear Instruments & Methods in Physics Research Section A. Roč. 729, NOV (2013), s. 302-306. ISSN 0168-9002. E-ISSN 1872-9576
    Grant CEP: GA MPO FR-TI1/412
    Institucionální podpora: RVO:68378271
    Klíčová slova: internal cooling * X-ray optics * monochromator
    Kód oboru RIV: BH - Optika, masery a lasery
    Impakt faktor: 1.316, rok: 2013

    Internally cooled X–ray optics, like X–ray monochromators and reflecting X–ray mirrors play a crucial role in defining a beamlines resolution, degree of coherence and flux. A great effort is invested in the development of these optical components. An important aspect of the functionality of high heat load optics is its cooling and its influence on surface deformation. The authors present a study of two different geometrical cooling approaches. It’s influence on beam inhomogeneity due to the strain from the manufacturing process is presented. X–ray topographic images and FWHM measurements are presented. FEA simulations of cooling efficiency and surface deformations was performed. The best achieved results are under an enlargement of 0.4 microrad of the measured rocking curve.
    Trvalý link: http://hdl.handle.net/11104/0226200

     
     